中文
相关论文

相关论文: Demonstration of a laserwire emittance scanner for…

200 篇论文

Within the framework of the LHC Injector Upgrade (LIU), the new LINAC4 is currently being commissioned to replace the existing LINAC2 proton source at CERN. After the expected completion at the end of 2016, the LINAC4 will accelerate H-…

加速器物理 · 物理学 2016-08-24 T. Hofmann , G. E. Boorman , A. Bosco , E. Bravin , S. M. Gibson , K. O. Kruchinin , U. Raich , F. Roncarolo , F. Zocca

A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 {\mu}m (vertical x…

Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced…

A tightly focused laser beam (laser wire) is used for measurement of transverse electron beam sizes in storage rings and linear colliders. It is assumed that the laser beam does nothing with the electron beam except Compton scatterings…

高能物理 - 实验 · 物理学 2015-06-25 V. I. Telnov

The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded…

Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for…

For injection of beams into circular machines with different horizontal and vertical emittance acceptance, the injection efficiency can be increased if these beams are flat, i.e. if they feature unequal transverse emittances. Generation of…

加速器物理 · 物理学 2011-08-01 Lars Groening

For the characterization of the 10 mA ion beam delivered by the new High Current Linac at GSI, sophisticated, mainly non-intersepting diagnostic devices were developed. Besides the general set-up of a versatile test bench, we discuss in…

加速器物理 · 物理学 2007-05-23 P. Forck , F. Heymach , T. Hoffmann , A. Peters , P. Strehl

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster…

加速器物理 · 物理学 2024-09-05 E. Chen , R. Sharankova , A. Shemyakin , J. Stanton

2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the…

加速器物理 · 物理学 2023-01-25 F Osswald , T Durand , M Heine , J Michaud , F Poirier , J C Thomas , E Traykov

Crossing a horizontal nonlinear resonance is the approach that can be used to split a beam in several beamlets with the goal to perform multi-turn extraction from a circular particle accelerator. Such an approach has been successfully…

加速器物理 · 物理学 2022-11-29 G. Russo , F. Cerutti , L. S. Esposito , G. Franchetti , M. Giovannozzi , J. R. Hunt , A. Huschauer

This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire…

The Free-Electron Laser Laboratory at the University of Hawai`i has constructed and tested a scanning wire beam position monitor to aid the alignment and optimization of a high spectral brightness inverse-Compton scattering x-ray source.…

加速器物理 · 物理学 2014-04-24 Michael R. Hadmack , Eric B. Szarmes

A common issue encountered in photoemission electron sources used in electron accelerators is the transverse inhomogeneity of the laser distribution resulting from the laser-amplification process and often use of frequency up conversion in…

加速器物理 · 物理学 2017-11-22 A. Halavanau , G. Qiang , G. Ha , E. Wisniewski , P. Piot , J. G. Power , W. Gai

A conceptual design work and a basic experimental study of a new beam profile monitor have been performed. The monitor will be used to measure emittance of an electron beam in the ATF damping ring at KEK, in which the transverse beam size…

The caesiated surface negative ion source is the first element of CERN's LINAC4 a linear injector designed to accelerate negative hydrogen ions to 160 MeV. The IS03 ion source is operated at 35 mA beam intensity and reliably feeds CERN's…

We report on the optical commissioning of the high power laser beam circulator (LBC) for the high brightness Compton {\gamma}-ray source Extreme Light Infrastructure for Nuclear Physics. Tests aiming at demonstrating the optical…

Laser beam scanning is central to many applications, including displays, microscopy, three-dimensional mapping, and quantum information. Reducing the scanners to microchip form factors has spurred the development of very-large-scale…

A novel emittance meter has been developed to measure the four-dimensional, transverse phase-space distribution of a low-energy ion beam using the pepper-pot technique. A characteristic feature of this instrument is that the pepper-pot…

仪器与探测器 · 物理学 2013-03-15 H. R. Kremers , J. P. M. Beijers , S. Brandenburg

Next generation hard X-ray free electron lasers require electron beams with low transverse emittance. One proposal to achieve these low emittances is to exploit the eigen-emittance values of the beam. The eigen-emittances are invariant…

‹ 上一页 1 2 3 10 下一页 ›