相关论文: A Calibration of NICMOS Camera 2 for Low Count-Rat…
We present a photometric analysis of all high Galactic lattitude (|b| > 20d) broad-band parallel images taken by the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) instrument during its initial lifetime in HST Cycle 7. These…
CMOS detectors offer many advantages over CCDs for optical and UV astronomical applications, especially in space where high radiation tolerance is required. However, astronomical instruments are most often designed for low light-level…
We present results from the application of a global photometric calibration (GPC) procedure to calibration data from the first 2 years of The Two Micron All Sky Survey (2MASS). The GPC algorithm uses photometry of both primary standards and…
The calibration and traceability of high resolution frequency modulated continuous wave (FMCW) ladar sources is a requirement for their use in length and volume metrology. We report the calibration of a FMCW ladar length measurement system…
Presently a ${>}3\sigma$ tension exists between values of the Hubble constant $H_0$ derived from analysis of fluctuations in the Cosmic Microwave Background by Planck, and local measurements of the expansion using calibrators of type Ia…
Photometric calibration is currently the dominant source of systematic uncertainty in exploiting type Ia supernovae to determine the nature of the dark energy. We review our ongoing program to address this calibration challenge by…
We present an expanded sample of 75 Milky Way Cepheids with Hubble Space Telescope (HST) photometry and Gaia EDR3 parallaxes which we use to recalibrate the extragalactic distance ladder and refine the determination of the Hubble constant.…
The absolute calibration and characterization of the Multiband Imaging Photometer for Spitzer (MIPS) 70 micron coarse- and fine-scale imaging modes are presented based on over 2.5 years of observations. Accurate photometry (especially for…
In order to measure distances with minimal systematics using the correlation between galaxy luminosities and rotation rates it is necessary to adhere to a strict and tested recipe. We now derive a measure of rotation from a new…
We present ``snapshot'' observations with the NearInfrared Camera and MultiObject Spectrometer (NICMOS) on board the Hubble Space Telescope (HST) of 94 nearby galaxies from the Revised Shapley Ames Catalog. Images with 0.2 as resolution…
An undersampled point spread function may interact with the microstructure of a solid-state detector such that the total flux detected can depend sensitively on where the PSF center falls within a pixel. Such intra-pixel sensitivity…
We present a recalibration of the Sloan Digital Sky Survey (SDSS) photometry with new flat fields and zero points derived from Pan-STARRS1 (PS1). Using PSF photometry of 60 million stars with $16 < r < 20$, we derive a model of amplifier…
Newly acquired data and improved data reduction algorithms mandate a fresh look at the absolute flux calibration of the CCD cameras on the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS). The goals are to achieve a 1\%…
This paper studies sensor calibration in spectral estimation where the true frequencies are located on a continuous domain. We consider a uniform array of sensors that collects measurements whose spectrum is composed of a finite number of…
The collections of spectral energy distributions (SEDs) in the \emph{Hubble Space Telescope} (HST) CALSPEC database are augmented by 19 IR SEDs from Wide Field Camera 3 (WFC3) IR grism spectra. Together, the two IR grisms, G102 and G141,…
The limiting factor of the accuracy of WFPC2 photometry is the CTE loss, which has increased to the level of 50% or more for faint stars at the top of the chips. I describe recent work on characterizing this effect, and provide improved…
The James Webb Space Telescope is orders of magnitude more sensitive than any other facility across the near to mid-infrared wavelengths. Many approved programs take advantage of its highly stable point spread function (PSF) to directly…
Near-infrared bandpasses on spaceborne observatories diverge from their ground-based counterparts as they are free of atmospheric telluric absorption. Available transformations between respective filter systems in the literature rely on…
The results from work done to extend the Johnson-Cousins BVRI photometric standard sequence to faint levels of V ~ 21 mag in compact fields is presented. Such calibration and extension of sequences is necessary to fill a calibration gap, if…
Accurate photometric redshifts are among the key requirements for precision weak lensing measurements. Both the large size of the Sloan Digital Sky Survey (SDSS) and the existence of large spectroscopic redshift samples that are…