中文
相关论文

相关论文: Fast Scatter Artifacts Correction for Cone-Beam CT…

200 篇论文

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

医学物理 · 物理学 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

医学物理 · 物理学 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

医学物理 · 物理学 2016-04-07 Shi-peng Xie , Rui-ju Yan

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

计算机视觉与模式识别 · 计算机科学 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

医学物理 · 物理学 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

信号处理 · 电气工程与系统科学 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter…

医学物理 · 物理学 2016-08-03 Kuidong Huang , Zhe Xu , Dinghua Zhang , Hua Zhang , Wenlong Shi

We present an effective post-processing method to reduce the artifacts from sparsely reconstructed cone-beam CT (CBCT) images. The proposed method is based on the state-of-the-art, image-to-image generative models with a perceptual loss as…

计算机视觉与模式识别 · 计算机科学 2018-12-11 Haofu Liao , Zhimin Huo , William J. Sehnert , Shaohua Kevin Zhou , Jiebo Luo

CBCT images suffer from acute shading artifacts primarily due to scatter. Numerous image-domain correction algorithms have been proposed in the literature that use patient-specific planning CT images to estimate shading contributions in…

计算机视觉与模式识别 · 计算机科学 2018-01-18 Awais Ashfaq , Jonas Adler

In this paper, an improved scatter correction with moving beam stop array (BSA) for x-ray cone beam (CB) CT is proposed. Firstly, correlation between neighboring CB views is deduced based on John's Equation. Then, correlation-based…

医学物理 · 物理学 2014-10-31 Hao Yan , Xuanqin Mou , Shaojie Tang , Qiong Xu

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

医学物理 · 物理学 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

计算机视觉与模式识别 · 计算机科学 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Scatter signals can degrade the contrast and resolution of computed tomography (CT) images and induce artifacts. How to effectively correct scatter signals in CT has always been a focal point of research for researchers. This work presents…

医学物理 · 物理学 2025-01-10 Guiyuan Lin , Shiwo Deng , Xiaoqun Wang , Xing Zhao

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

计算工程、金融与科学 · 计算机科学 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or…

计算机视觉与模式识别 · 计算机科学 2024-03-28 Mohammadreza Amirian , Daniel Barco , Ivo Herzig , Frank-Peter Schilling

Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…

医学物理 · 物理学 2020-01-13 Jonathan H. Mason , Alessandro Perelli , William H. Nailon , Mike E. Davies

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART)…

High quality reconstruction with interventional C-arm cone-beam computed tomography (CBCT) requires exact geometry information. If the geometry information is corrupted, e. g., by unexpected patient or system movement, the measured signal…

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

图像与视频处理 · 电气工程与系统科学 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

Background: Cone-beam computed tomography (CBCT) scans, performed fractionally (e.g., daily or weekly), are widely utilized for patient alignment in the image-guided radiotherapy (IGRT) process, thereby making it a potential imaging…

‹ 上一页 1 2 3 10 下一页 ›