中文
相关论文

相关论文: Improved Scatter Correction in X-Ray Cone Beam CT …

200 篇论文

We study active array imaging of small but strong scatterers in homogeneous media when multiple scattering between them is important. We use the Foldy-Lax equations to model wave propagation with multiple scattering when the scatterers are…

数学物理 · 物理学 2015-12-15 Anwei Chai , Miguel Moscoso , George Papanicolaou

Back-illuminated charged-coupled device (BI-CCD) arrays increase quantum efficiency but also amplify etaloning, a multiplicative, wavelength-dependent fixed-pattern effect. When spectral data from hundreds of BI-CCD rows are combined, the…

光学 · 物理学 2021-07-26 Christine Massie , Keren Chen , Andrew J. Berger

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

计算机视觉与模式识别 · 计算机科学 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

A ray-tracing (RT) enhanced back-projection algorithm (RT-BPA) for microwave imaging in multipath environments is presented. By tightly incorporating the concept of ray-tracing into a generalized version of traditional BPA, this method…

图像与视频处理 · 电气工程与系统科学 2026-05-12 Han Na , Quanfeng Wang , Matthias Saurer , Meisong Tong , Thomas F. Eibert

Blind source separation (BSS) is one of the most important and established research topics in signal processing and many algorithms have been proposed based on different statistical properties of the source signals. For second-order…

数值分析 · 数学 2014-03-11 Wei Liu

Three-photon (3P) microscopy is getting traction due to its superior performance in deep tissues. Yet, aberrations and light scattering still pose one of the main limitations in the attainable depth ranges for high-resolution imaging. Here,…

光学 · 物理学 2022-12-06 Bernhard Rauer , Hilton B. de Aguiar , Laurent Bourdieu , Sylvain Gigan

We propose a method for the computation of a consistent system matrix for two- and three-dimensional cone-beam computed tomography (CT). The method relies on the decomposition of the cone-voxel intersection volumes into subvolumes that…

最优化与控制 · 数学 2025-11-18 Josef Simbrunner , Clemens Krenn , Martin Zach , Andreas Habring

This paper proposes a sinogram consistency learning method to deal with beam-hardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent…

医学物理 · 物理学 2019-06-06 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo

Offering high-brilliance X-ray beams on micrometer length scales, the microfocus-SAXS at SSRF BL16B1 was established with a KB mirror system for studying small sample volumes, or probing micro-scopic morphologies. The SAXS minimum q value…

仪器与探测器 · 物理学 2017-01-05 Wenqiang Hua , Yuzhu Wang , Ping Zhou , Tao Hu , Xiuhong Li , Fenggang Bian , Jie Wang

Representational similarity analysis (RSA) is a multivariate technique to investigate cortical representations of objects or constructs. While avoiding ill-posed matrix inversions that plague multivariate approaches in the presence of many…

统计方法学 · 统计学 2021-12-03 Roberto Viviani

Context. The best precision that can be achieved to estimate the location of a stellar-like object is a topic of permanent interest in the astrometric community. Aims. We analyse bounds for the best position estimation of a stellar-like…

天体物理仪器与方法 · 物理学 2016-10-26 Alex Echeverria , Jorge F. Silva , Rene A. Mendez , Marcos Orchard

Industrial CT is useful for defect detection, dimensional inspection and geometric analysis. While it does not meet the needs of industrial mass production, because of its time-consuming imaging procedure. This article proposes a novel…

仪器与探测器 · 物理学 2022-06-20 Zheng Fang , Tingjun Wang , Bingan Yuan , Xinlin Qing , Shunren Li

Sparse-view computed tomography (CT) is known as a widely used approach to reduce radiation dose while accelerating imaging through lowered projection views and correlated calculations. However, its severe imaging noise and streaking…

图像与视频处理 · 电气工程与系统科学 2021-01-20 Yitong Liu , Ken Deng , Chang Sun , Hongwen Yang

X-ray Bragg coherent diffraction imaging has been demonstrated as a powerful three-dimensional (3D) microscopy approach for the investigation of sub-micrometer-scale crystalline particles. It is based on the measurement of a series of…

Ultra low radiation dose in X-ray Computed Tomography (CT) is an important clinical objective in order to minimize the risk of carcinogenesis. Compressed Sensing (CS) enables significant reductions in radiation dose to be achieved by…

Stereotactic body radiotherapy (SBRT) is characterized by delivering a high amount of dose in a short period of time. In SBRT the dose is delivered using open fields (e.g., beam's-eye-view) known as "apertures". Mathematical methods can be…

医学物理 · 物理学 2015-06-15 Hamed Yarmand , David Craft

Cone-beam computed tomography (CBCT) is a widely used 3D imaging technique in dentistry, offering high-resolution images while minimising radiation exposure for patients. However, CBCT is highly susceptible to artefacts arising from…

计算机视觉与模式识别 · 计算机科学 2026-03-09 Susanne Schaub , Florentin Bieder , Matheus L. Oliveira , Yulan Wang , Dorothea Dagassan-Berndt , Michael M. Bornstein , Philippe C. Cattin

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

We introduce a charge coupled device (CCD) camera based detection scheme in dynamic light scattering that provides information on the single-scattered auto-correlation function even for fairly turbid samples. It is based on the single…

软凝聚态物质 · 物理学 2009-11-11 Pavel Zakharov , Suresh Bhat , Peter Schurtenberger , Frank Scheffold

The Brighter-Fatter (hereafter BF) effect in CCD sensors causes increases in the image size of bright objects due to electrostatic repulsion of collected charges. Correcting this effect in the LSST camera is required in order to meet the…

天体物理仪器与方法 · 物理学 2019-11-22 Craig Lage