中文
相关论文

相关论文: The NIM Inertial Mass Measurement Project

200 篇论文

The development of the joule balance method to measure the Planck constant, in support of the redefinition of the kilogram, has been going on at the National Institute of Metrology of China (NIM) since 2007. The first prototype has been…

仪器与探测器 · 物理学 2014-12-23 Zhengkun Li , Zhonghua Zhang , Qing He , Bing Han , Yunfeng Lu , Jinxin Xu , Shisong Li , Chen Li , Gang Wnag , Tao Zeng , Yang Bai

A new watt balance is being constructed at the National Institute of Standards and Technology (NIST) in preparation for the redefinition of the International System of Units and the realization of mass through an exact value of the Planck…

仪器与探测器 · 物理学 2016-11-15 E. J. Leaman , D. Haddad , F. Seifert , L. S. Chao , A. Cao , J. R. Pratt , S. Schlamminger , D. B. Newell

Researchers at the National Institute of Standards and Technology(NIST) have measured the value of the Planck constant to be $h =6.626\,069\,934(89)\times 10^{-34}\,$J$\,$s (relative standard uncertainty $13\times 10^{-9}$). The result is…

仪器与探测器 · 物理学 2017-08-09 D. Haddad , F. Seifert , L. S. Chao , A. Possolo , D. B. Newell , J. R. Pratt , C. J. Williams , S. Schlamminger

The Planck constant $h$ is one of the most significant constants in quantum physics. Recently, the precision measurement of the numeral value of $h$ has been a hot issue due to its important role in establishment for both a new SI and a…

仪器与探测器 · 物理学 2015-06-23 Shisong Li , Zhonghua Zhang , Wei Zhao , Zhengkun Li , Songling Huang

A Kibble balance measures the $gravitational$ mass (weight) of a test mass with extreme precision by balancing the gravitational pull on the test mass against the electromagnetic lift force. The uncertainty in such mass measurement is…

综合物理 · 物理学 2024-03-05 Rajendra P. Gupta

We propose two experimental schemes to determine and so to realize the Avogadro constant $N\_{A}$ at the level of 10$^{-7}$ or better with a watt balance experiment and a cold atom experiment measuring $h/m(X)$ (where $h$ is the Planck…

Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant $h$ for over ten years. Two recently published values disagree by more than one standard uncertainty.…

仪器与探测器 · 物理学 2015-06-23 S. Schlamminger , R. L. Steiner , D. Haddad , D. B. Newell , F. Seifert , L. S. Chao , R. Liu , E. R. Williams , J. R. Pratt

Precision measurements of the fundamental constants are tour de force of basic metrology, where the useful information is usually beyond the last digit of the measured value. They challenge theoretical models and measurement technologies…

仪器与探测器 · 物理学 2020-07-21 Horst Bettin , Kenichi Fujii , John Man , Giovanni Mana , Enrico Massa , Alain Picard

With the redefinition of the international system of units, the value of the Planck constant was fixed, similarly to the values of the unperturbed ground state hyperfine transition frequency of the $^{133}$Cs atom, speed of light in vacuum.…

经典物理 · 物理学 2022-08-24 Giovanni Mana , Stephan Schlamminger

To establish a closer contact between school and experimental sciences, Sapienza Universit\`a di Roma and the Istituto Nazionale di Fisica Nucleare (INFN) launched the Lab2Go project. Lab2Go has the goal of spreading laboratory practice…

The proposed PINGU experiment to measure the neutrino mass hierarchy is presented, in the context of long-range planning by the U.S. nuclear physics community.

仪器与探测器 · 物理学 2019-08-14 D. F. Cowen , T. DeYoung , D. Grant , D. A. Dwyer , S. R. Klein , K. B. Luk , D. R. Williams

For the past two years, measurements have been performed with a watt balance at the National Institute of Standards and Technology (NIST) to determine the Planck constant. A detailed analysis of these measurements and their uncertainties…

Newton's constant is the least well-measured among the fundamental constants of Nature, and, indeed, its accurate measurement has long served an experimental challenge. Levitated mechanical systems are attracting growing attention for their…

量子物理 · 物理学 2026-02-18 Francis J. Headley , Alessio Belenchia , Mauro Paternostro , Daniel Braun

In early 2014, construction of a new watt balance, named NIST-4, has started at the National Institute of Standards and Technology (NIST). In a watt balance, the gravitational force of an unknown mass is compensated by an electromagnetic…

仪器与探测器 · 物理学 2016-11-15 D. Haddad , F. Seifert , L. S. Chao , A. Cao , G. Sineriz , J. R. Pratt , D. B. Newell , S. Schlamminger

A precision measurement of the gravitational constant $G$ has been made using a beam balance. Special attention has been given to determining the calibration, the effect of a possible nonlinearity of the balance and the zero-point variation…

广义相对论与量子宇宙学 · 物理学 2008-11-26 St. Schlamminger , E. Holzschuh , W. Kündig , F. Nolting , R. E. Pixley , J. Schurr , U. Straumann

Applications of inertial measurement units are extremely diverse, and are expected to see a further increase in number due to current trends in robotics as well as recent advances in Micro Electromechanical sensors (MEMS). The traditional…

机器人学 · 计算机科学 2017-08-16 William T. Conlin

The UME Kibble balance project was initiated at the second half of 2014. During this period we have studied the theoretical aspects of Kibble balances in which an oscillating magnet generates AC Faraday voltage in a stationary coil and…

仪器与探测器 · 物理学 2018-04-18 H Ahmedov , N Babayigit Askin , B Korutlu , R Orhan

It is shown that the inert properties of a stationary random process can be expressed in terms of the ratio of its correlation interval to the doubled variance. When using a fixed value of the Planck constant h as a proportionality factor,…

综合物理 · 物理学 2022-10-10 Mikhail Batanov-Gaukhman

The Newtonian constant of gravitation $G$ historically has the largest relative uncertainty over all other fundamental constants with some discrepancies in values between different measurements. We propose a new scheme to measure $G$ by…

仪器与探测器 · 物理学 2020-03-02 Akio Kawasaki

The measurement of the Avogadro constant opened the way to a comparison of the watt-balance measurements of the Planck constant with the values calculated from the quotients of the Planck constant and the mass of a particle or an atom.…

数据分析、统计与概率 · 物理学 2015-03-19 Enrico Massa , Giovanni Mana , Michael Jentschel
‹ 上一页 1 2 3 10 下一页 ›