中文
相关论文

相关论文: Silica aerogel radiator for use in the A-RICH syst…

200 篇论文

We report recent progress in the development of large-area hydrophobic silica aerogels for use as radiators in the aerogel-based ring-imaging Cherenkov (A-RICH) counter to be installed in the forward end cap of the Belle II detector, which…

仪器与探测器 · 物理学 2014-11-18 Makoto Tabata , Ichiro Adachi , Hideyuki Kawai , Shohei Nishida , Takayuki Sumiyoshi

This study presents the development of large-area (18 $\times $ 18 $\times $ 2 cm$^3$), high refractive index ($n \sim $1.05) hydrophobic silica aerogel tiles for use as Cherenkov radiators. These transparent aerogel tiles will be installed…

This paper reports the successful fabrication of silica aerogel Cherenkov radiators produced in the first batches from a 96-tile mass production performed using pin-drying technique in our laboratory. The aerogels are to be used in a…

We report on the design, operation, and performance of a novel proximity-focusing Ring Imaging Cherenkov (RICH) detector equipped with a multilayer focusing aerogel radiator, developed for the forward region of the Belle II spectrometer at…

This study presents the development of hydrophobic silica aerogel for use as a radiator in threshold-type Cherenkov counters. These counters are to be used for separating positrons and positive muons produced by kaon decay in the J-PARC…

A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4 GeV/c pion beams at KEK. Essentially, a multiple refractive index…

In this paper, we present recent progress in the development of hydrophobic silica aerogel as a Cherenkov radiator. In addition to the conventional method, the recently developed pin-drying method for producing high-refractive-index…

仪器与探测器 · 物理学 2012-10-03 Makoto Tabata , Ichiro Adachi , Hideyuki Kawai , Masato Kubo , Takeshi Sato

A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for an upgrade of the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel…

We have developed a new type of particle identification device, called an Aerogel Ring Imaging Cherenkov (ARICH) counter, for the Belle II experiment. It uses silica aerogel tiles as Cherenkov radiators. For detection of Cherenkov photons,…

This study presents the advancement in hydrophobic silica aerogel development for use as Cherenkov radiators and muonium production targets. These devices are scheduled for use in several particle- and nuclear-physics experiments that are…

仪器与探测器 · 物理学 2017-08-23 Makoto Tabata , Hideyuki Kawai

We present optical and X-ray radiographical characterization of silica aerogels with refractive index from 1.05 to 1.07 for a Cherenkov radiator. A novel pin-drying method enables us to produce highly transparent hydrophobic aerogels with…

仪器与探测器 · 物理学 2014-11-18 Makoto Tabata , Ichiro Adachi , Yoshikiyo Hatakeyama , Hideyuki Kawai , Takeshi Morita , Keiko Nishikawa

The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions and kaons with momenta up to $4 \, {\rm GeV}/c$ by…

To identify $\pi^{\pm}$ and $K^{\pm}$ in the region of $1.0\sim 2.5$ GeV/c, a threshold Cherenkov counter equipped with silica aerogels has been investigated. Silica aerogels with a low refractive index of 1.013 have been successfully…

高能物理 - 实验 · 物理学 2009-10-22 I. Adachi et al

New highly transparent, hydrophobic silica aerogels with refractive indices of 1.01 to 1.07 have been produced by Aspen Aerogels, Inc., and select tiles have been tested using an electron beam at the DESY, Hamburg facility. A…

仪器与探测器 · 物理学 2018-01-15 D. Blyth , R. Alarcon , R. Begag , J. Holmes , J. Stryker

Using aerogel as radiator and multianode PMTs for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK $\pi$2 beam. The aim is to experimentally study the basic parameters such as…

Silica aerogels are important to be used as photon radiators in Cherenkov counters for high-energy-physics experiments because of their optical transparency and intermediate refractive indices between those of gases and liquids or solids.…

仪器与探测器 · 物理学 2023-10-10 Makoto Tabata

The ALICE Collaboration is proposing a completely new apparatus, ALICE~3, for the LHC Runs~5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov…

In the forward end-cap of the Belle II spectrometer, particle identification is provided by a proximity focusing RICH detector with an aerogel radiator (ARICH). The ARICH's primary function is to effectively distinguish between pions and…

仪器与探测器 · 物理学 2023-08-09 Luka Santelj

We have succeeded in developing hydrophobic silica aerogels over a wide range of densities (i.e. refractive indices). A pinhole drying method was invented to make possible producing highly transparent aerogels with entirely new region of…

仪器与探测器 · 物理学 2011-12-22 Makoto Tabata , Ichiro Adachi , Yoshikazu Ishii , Hideyuki Kawai , Takayuki Sumiyoshi , Hiroshi Yokogawa

This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key…

仪器与探测器 · 物理学 2012-12-17 Makoto Tabata , Yoshikiyo Hatakeyama , Ichiro Adachi , Takeshi Morita , Keiko Nishikawa
‹ 上一页 1 2 3 10 下一页 ›