相关论文: X-ray detection with Micromegas with background le…
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…
We propose a new strategy to search for dark matter axions in the mass range of 40--400 $\mu$eV by introducing dielectric haloscopes, which consist of dielectric disks placed in a magnetic field. The changing dielectric media cause…
An x-ray detector for a solar axion search was developed. The detector is operated at 60K in a cryostat of a superconducting magnet. Special care was paid to microphonic noise immunity and mechanical structure against thermal contraction.…
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0\nu\beta\beta$) in…
Recently CMOS (complementary metal-oxide semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray…
Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time…
The CONUS experiment is searching for coherent elastic neutrino nucleus scattering of reactor anti-neutrinos with four low energy threshold point-contact high-purity germanium spectrometers. An excellent background suppression within the…
We present the first sky maps from the BEAST (Background Emission Anisotropy Scanning Telescope) experiment. BEAST consists of a 2.2 meter off axis Gregorian telescope fed by a cryogenic millimeter wavelength focal plane currently…
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…
The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors…
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module…
We are currently setting up a facility for low-background gamma-ray spectrometry based on a HPGe detector. It is dedicated to material screening for the XENON and DARWIN dark matter projects as well as to the characterization of meteorites.…
The detection of photons above 10 keV through MeV and GeV energies is challenging due to the penetrating nature of the radiation, which can require large detector volumes, resulting in correspondingly high background. In this energy range,…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last…
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The platform is…
The CAST experiment is being mounted at CERN. It will make use of a decommissioned LHC test magnet to look for solar axions through its conversion into photons inside the magnetic field. The magnet has a field of 9 Tesla and length of 10 m…
The search for weakly interacting, light particles that couple to photons received significant attention in recent years. When those particles are produced at high energies, they lead to two, nearly collinear photons after their decay and…
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows…