相关论文: Systematic grid-wise radon concentration measureme…
Resistive AC-coupled Silicon Detectors (RSDs) are silicon sensors which provide high temporal and spatial resolution. The RSD is a candidate sensor to be used in future tracking detectors with the objective of obtaining '4D' tracking, where…
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related…
The Very Small Array (VSA) has been used to survey the l = 27 to 46 deg, |b|<4 deg region of the Galactic plane at a resolution of 13 arcmin. The survey consists of 44 pointings of the VSA, each with a r.m.s. sensitivity of ~90 mJy/beam.…
The Daya Bay reactor neutrino experiment has observed the disappearance of electron antineutrinos from nuclear reactors at $\sim$kilometer baselines. The relative measurement of the $\bar\nu_e$ rate and spectrum between near and far…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
A three-dimensional (3D) electrochemical flow-through reactor equipped with GAC packed bed, polarized by the electric field, was evaluated for the removal of persistent organic contaminants from real sewage effluent. The performance of the…
The radiological doses and hazard indices of natural radionuclides $^{238}$U,$^{232}$Th and $^{40} $K in soil samples from Kerbala city were evaluated using gamma-ray spectroscopy system using NaI(Tl) ${"1.5\times 2"}$ detector in…
A new technique for on-line high resolution isotopic analysis of liquid water, tailored for ice core studies is presented. We built an interface between a Wavelength Scanned Cavity Ring Down Spectrometer (WS-CRDS) purchased from Picarro…
Radon is a significant background source in rare event detection experiments. Activated Carbon (AC) adsorption is widely used for effective radon removal. The selection of AC considers its adsorption capacity and radioactive background. In…
The Daya Bay experiment measures sin^2 2{\theta}_13 using functionally identical antineutrino detectors located at distances of 300 to 2000 meters from the Daya Bay nuclear power complex. Each detector consists of three nested fluid volumes…
We present the results of the operation of an array of avalanche photodiodes (APDs) for the readout of an electroluminescence detector. The detector contains 24 APDs with a pitch of 15 mm between them allowing energy and position…
This study proposes a multi-radar system for non-contact physiological sensing across arbitrary body orientations. In integrating signals obtained from different radar viewpoints, we adopt a multivariate variational mode decomposition…
Millimeter-wave (mmWave) radars have found applications in a wide range of domains, including human tracking, health monitoring, and autonomous driving, for their unobtrusive nature and high range accuracy. These capabilities, however, if…
The air dose rate in an environment contaminated with 134Cs and 137Cs depends on the amount, depth profile and horizontal distribution of these contaminants within the ground. This paper introduces and verifies a tool that models these…
The Jiangmen Underground Neutrino Observatory is building the world's largest liquid scintillator detector with a 20 kt target mass and about 700 m overburden. The total underground space of civil construction is about 300,000 m$^3$ with…
A method is proposed for deriving the dispersion measure (related to the line-of-sight integrated free electron density) to high-redshift, powerful synchrotron radio sources by analysis of the temporal/spectral properties of the recorded…
The AMADEUS system is an integral part of the ANTARES neutrino telescope in the Mediterranean Sea. The project aims at the investigation of techniques for acoustic neutrino detection in the deep sea. Installed at a depth of more than 2000m,…
We have developed a scanning photoluminescence technique that can directly map out the local two-dimensional electron density with a relative accuracy of $\sim2.2\times10^8$ cm$^{-2}$. The validity of this approach is confirmed by the…
The acquisition and use of mobile phone is tremendously increasing especially in developing countries, but not without a concern. The greater concern among the public is principally over the proximity of mobile base stations (MBS) to…
The results of the analysis of the data collected with the NEMO Phase-2 tower, deployed at 3500 m depth about 80 km off-shore Capo Passero (Italy), are presented. Cherenkov photons detected with the photomultipliers tubes were used to…