A high performance gas displacement pump based on four individual cylinders was developed. The magnetically-coupled pistons and the hermetically-sealed housings as well as the special cleanliness in terms of out-gassing and radio-purity…

仪器与探测器 · 物理学 2021-09-15 D. Schulte , M. Murra , P. Schulte , C. Huhmann , C. Weinheimer

Experiments based on noble elements such as gaseous or liquid argon or xenon utilize the ionization and scintillation properties of the target materials to detect radiation-induced recoils. A requirement for high light and charge yields is…

We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas…

Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through…

仪器与探测器 · 物理学 2011-03-08 K. L. Giboni , E. Aprile , B. Choi , T. Haruyama , R. F. Lang , K. E. Lim , A. J. Melgarejo , G. Plante

In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and…

We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces…

We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more…

软凝聚态物质 · 物理学 2007-05-23 R. W. Mair , R. Wang , M. S. Rosen , D. Candela , D. G. Cory , R. L. Walsworth

Metastable states of noble gas atoms are typically produced by electrical discharge techniques or "all-optical" excitation methods. Here we combine electrical discharges with optical pumping to demonstrate "optically enhanced" production of…

原子物理 · 物理学 2017-10-10 G. T. Hickman , J. D. Franson , T. B. Pittman

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

仪器与探测器 · 物理学 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

We describe the design and operation of a system for xenon liquefaction in which the condenser is separated from the liquid storage vessel. The condenser is cooled by a pulse tube cryocooler, while the vessel is cooled only by the liquid…

仪器与探测器 · 物理学 2015-05-13 S. Slutsky , Y. -R. Yen , H. Breuer , A. Dobi , C. Hall , T. Langford , D. S. Leonard , L. J. Kaufman , V. Strickland , N. Voskanian

We report on the development and performance of a high-sensitivity purity-analysis technique for gaseous xenon. The gas is sampled at macroscopic pressure from the system of interest using a UHV leak valve. The xenon present in the sample…

仪器与探测器 · 物理学 2011-05-09 D. S. Leonard , A. Dobi , C. Hall , L. Kaufman , T. Langford , S. Slutsky , Y. R. Yen

Oxygen, nitrogen and methane purification efficiencies for a common zirconium getter are measured in 1050 Torr of xenon gas. Starting with impurity concentrations near 10^{-6} g/g, the outlet impurity level is found to be less than…

仪器与探测器 · 物理学 2011-05-09 A. Dobi , D. S. Leonard , C. Hall , L. Kaufman , T. Langford , S. Slutsky , Y. R. Yen

A high pumping speed is required in neutral beam injectors to minimise re-ionisation of the neutral beams. The neutral beam injectors on MAST use titanium sublimation pumps. These pumps do not have a constant pumping speed; their pumping…

加速器物理 · 物理学 2015-10-29 R McAdams

As liquid xenon detectors grow in scale, novel techniques are required to maintain sufficient purity for charges to survive across longer drifts. The Xeclipse test facility at Columbia University was built to test the removal of…

仪器与探测器 · 物理学 2022-10-05 G. Plante , E. Aprile , J. Howlett , Y. Zhang

A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal…

仪器与探测器 · 物理学 2015-06-12 Ethan Brown , Stephan Rosendahl , Christian Huhmann , Christian Weinheimer , Hans Kettling

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as…

仪器与探测器 · 物理学 2026-04-23 P. Schulte , D. Wenz , L. Althueser , R. Braun , V. Hannen , C. Huhmann , D. Koke , Y. -T. Lin , P. Unkhoff , C. Weinheimer

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…

仪器与探测器 · 物理学 2022-02-23 N. Ackerman , J. Albert , M. Auger , D. J. Auty , I. Badhrees , P. S. Barbeau , L. Bartoszek , E. Baussan , V. Belov , C. Benitez-Medina , T. Bhatta , M. Breidenbach , T. Brunner , G. F. Cao , W. R. Cen , C. Chambers , B. Cleveland , R. Conley , S. Cook , M. Coon , W. Craddock , A. Craycraft , W. Cree , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , C. G. Davis , J. Davis , S. Delaquis , A. Der Mesrobian-Kabakian , R. deVoe , T. Didberidze , J. Dilling , A. Dobi , A. G. Dolgolenko , M. J. Dolinski , M. Dunford , J. Echevers , L. Espic , W. Fairbank , D. Fairbank , J. Farine , W. Feldmeier , S. Feyzbakhsh , P. Fierlinger , K. Fouts , D. Franco , D. Freytag , D. Fudenberg , P. Gautam , G. Giroux , R. Gornea , K. Graham , G. Gratta , C. Hagemann , C. Hall , K. Hall , G. Haller , E. V. Hansen , C. Hargrove , R. Herbst , S. Herrin , J. Hodgson , M. Hughes , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , A. Johnson , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , F. Leonard , F. LePort , G. S. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , D. Mackay , R. MacLellan , M. Marino , J. -M. Martin , Y. Martin , T. McElroy , K. McFarlane , T. Michel , B. Mong , D. C. Moore , K. Murray , R. Neilson , O. Njoya , O. Nusair , K. O'Sullivan , A. Odian , I. Ostrovskiy , C. Ouellet , A. Piepke , A. Pocar , C. Y. Prescott , K. Pushkin , F. Retiere , A. Rivas , A. L. Robinson , E. Rollin , P. C. Rowson , M. P. Rozo , J. Runge , J. J. Russell , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , S. Slutsky , E. Smith , A. K. Soma , V. Stekhanov , V. Strickland , M. Swift , M. Tarka , J. Todd , T. Tolba , D. Tosi , T. I. Totev , R. Tsang , K. Twelker , B. Veenstra , V. Veeraraghavan , J. -L. Vuilleumier , J. -M. Vuilleumier , M. Wagenpfeil , A. Waite , J. Walton , T. Walton , K. Wamba , J. Watkins , M. Weber , L. J. Wen , U. Wichoski , M. Wittgen , J. Wodin , J. Wood , G. Wrede , S. X. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Ya Zeldovich , T. Ziegler

We report the use of an atomic magnetometer based on nonlinear magneto-optical rotation with frequency modulated light (FM NMOR) to detect nuclear magnetization of xenon gas. The magnetization of a spin-exchange-polarized xenon sample ($1.7…