中文
相关论文

相关论文: Calibration of a solid state nuclear track detecto…

200 篇论文

Two widely used methods of determining the etch-rate ratio in poly-ethylene terephthalate (PET) nuclear track detector are compared. Their application in different regimes of ion$\textquoteright$s energy loss is investigated. A new…

仪器与探测器 · 物理学 2018-10-17 R. Bhattacharyya , S. Dey , Sanjay K. Ghosh , Akhil Jhingan , A. Maulik , L. Patrizii , Sibaji Raha , D. Syam , V. Togo

The nuclear track detector CR39 was calibrated with different ions of different energies. Due to the low detection threshold (Z/beta~6e) and the good charge resolution (sigma_Z ~ 0.2e for 6e < Z/beta <83e with 2 measurements), the detector…

仪器与探测器 · 物理学 2010-03-04 Miriam Giorgini

The calibration of the CR39 and Makrofol Nuclear Track Detectors of the MoEDAL experiment at the CERN-LHC was performed by exposing stacks of detector foils to heavy ion beams with energies ranging from 340 MeV/nucleon to 150 GeV/nucleon.…

仪器与探测器 · 物理学 2025-10-06 M. Kalliokoski , G. Levi , A. Maulik , I. Ostrovskiy , L. Patrizii , J. Pinfold , Z. Sahnoun , G. Sirri , R. Soluk , M. Staelens , V. Togo , A. Upreti

Various phenomenological models presented over the years have hinted at the possible presence of strangelets, which are nuggets of Strange Quark Matter (SQM), in cosmic rays. One way to search for such rare events is through the deployment…

仪器与探测器 · 物理学 2017-04-24 R. Bhattacharyya , S. Dey , Sanjay K. Ghosh , A. Maulik , Sibaji Raha , D. Syam

Several improvements were made for Nuclear Track Detectors (NTDs) used for environmental studies and for particle searches. A new method was used to determine the bulk etch rate of CR39 and Makrofol NTDs. It is based on the simultaneous…

A high-granularity telescope system with a large sensitive area and low material budget has been developed for high-energy heavy ion beam tests. The telescope consists of nine layers of silicon microstrip detectors (SSDs), whose performance…

One of the main purposes of the DArk Matter Particle Explorer (DAMPE) is to measure the cosmic ray nuclei up to several tens of TeV or beyond, whose origin and propagation remains a hot topic in astrophysics. The Plastic Scintillator…

In this paper we present a method for single track coincidence measurements using two different track detector materials. We employed plastic and fluorescent nuclear track detectors (PNTDs and FNTDs) in the entrance channel of a…

DArk Matter Particle Explorer (DAMPE) is a space-borne apparatus for detecting the high-energy cosmic-rays like electrons, $\gamma$-rays, protons and heavy-ions. Plastic Scintillator Detector (PSD) is the top-most sub-detector of the DAMPE.…

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z…

Time over dynamic threshold (TODT) method, proposed in our previous work, has been successfully used for nuclear pulse charge measurement in PET detectors. It has advantages of strict linearity, large dynamic range, and better energy…

仪器与探测器 · 物理学 2018-06-08 Zhengqi Song , Yonggang Wang , Yong Xiao , Qiang Cao

For the high granularity and high energy resolution, Silicon Strip Detector (SSD) is widely applied in assembling telescopes to measure the charged particles in heavy ion reactions. In this paper, we present a novel method to achieve track…

A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…

In the past 20 years the search for neutrinoless double beta decay has driven many developements in all kind of detector technology. A new branch in this field are highly-pixelated semiconductor detectors - such as the CdTe-Timepix…

仪器与探测器 · 物理学 2015-06-19 Mykhaylo Filipenko , Thomas Gleixner , Gisela Anton , Thilo Michel

The detection of an electron bunch exiting a strong magnetic field can prove challenging due to the small mass of the electron. If placed too far from a solenoid's entrance, a detector outside the magnetic field will be too small to…

The mass concentrations of Th-232 and U-238 in several strong, unfilled, high performance polymers are reported as measures of their radiopurity. Highly radiopure polymers are required as dielectric materials in the construction of rare…

Thermal neutron detectors are crucial to a wide range of applications, including nuclear safety and security, cancer treatment, space research, non-destructive testing, and more. However, neutrons are notoriously difficult to capture due to…

Application of the nuclear track emulsion technique (NTE) in radioactivity and nuclear fission studies is discussed. It is suggested to use a HSP-1000 automated microscope for searching for a collinear cluster tri-partition of heavy nuclei…

When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…