中文
相关论文

相关论文: A cryogenic waveplate rotator for polarimetry at m…

200 篇论文

Several on-going and future experiments use a Stokes polarimeter (i.e. a rotating wave plate followed by a steady polarizer and by an unpolarized detector) to measure the small polarized component of the Cosmic Microwave Background. The…

天体物理仪器与方法 · 物理学 2010-06-17 Maria Salatino , Paolo de Bernardis

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based,…

天体物理仪器与方法 · 物理学 2022-04-27 G. D'Alessandro , L. Mele , F. Columbro , G. Amico , E. S. Battistelli , P. de Bernardis , A. Coppolecchia , M. De Petris , L. Grandsire , J. -Ch. Hamilton , L. Lamagna , S. Marnieros , S. Masi , A. Mennella , C. O'Sullivan , A. Paiella , F. Piacentini , M. Piat , G. Pisano , G. Presta , A. Tartari , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Bélier , A. Baù , D. Bennett , L. Bergé , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , C. Chapron , R. Charlassier , A. C. Cobos Cerutti , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. García , M. E. García Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gómez Berisso , M. González , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versillé , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , A. May , M. McCulloch , D. Melo , L. Montier , L. Mousset , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , L. Piccirillo , M. Platino , G. Polenta , D. Prêle , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , A. Schillaci , C. G. Scóccola , S. Scully , S. Spinelli , G. Stankowiak , M. Stolpovskiy , A. D. Supanitsky , J. -P. Thermeau , P. Timbie , M. Tomasi , G. Tucker , C. Tucker , D. Viganò , N. Vittorio , F. Wicek , M. Wright , A. Zullo

Controlling polarisation directly at low temperature is crucial for development of optical spectroscopy techniques at sub-Kelvin temperatures, for example, in a hybrid scheme where light is fed into and collected in the cryostat by fibres…

光学 · 物理学 2025-01-07 Thierry Chanelière , Alexei D. Chepelianskii

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a…

仪器与探测器 · 物理学 2021-09-22 T. A. Wilkinson , C. E. Maurer , C. J. Flood , G. Lander , S. Chafin , E. B. Flagg

A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ…

光学 · 物理学 2021-11-16 Vitaly Wirthl , Cristian D. Panda , Paul W. Hess , Gerald Gabrielse

Measurements of the polarization of the cosmic microwave background (CMB) radiation are expected to significantly increase our understanding of the early universe. We present a design for a CMB polarimeter in which a cryogenically cooled…

天体物理学 · 物理学 2016-11-17 S. Hanany , T. Matsumura , B. Johnson , T. Jones , J. R. Hull , K. B. Ma

An easily constructed and operated polarimeter precisely determines the relative Stokes parameters that characterize the polarization of laser light. The polarimeter is calibrated in situ without removing or realigning its optical elements,…

仪器与探测器 · 物理学 2021-02-22 V. Wirthl , C. D. Panda , P. W. Hess , B. Spaun , G. Gabrielse

We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…

天体物理仪器与方法 · 物理学 2012-05-01 M. Hasegawa , O. Tajima , Y. Chinone , M. Hazumi , K. Ishidoshiro , M. Nagai

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic…

天体物理仪器与方法 · 物理学 2022-04-27 S. Masi , E. S. Battistelli , P. de Bernardis , C. Chapron , F. Columbro , G. D'Alessandro , M. De Petris , L. Grandsire , J. -Ch. Hamilton , S. Marnieros , L. Mele , A. May , A. Mennella , C. O'Sullivan , A. Paiella , F. Piacentini , M. Piat , L. Piccirillo , G. Presta , A. Schillaci , A. Tartari , J. -P. Thermeau , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , G. Amico , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Bélier , A. Baù , D. Bennett , L. Bergé , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , R. Charlassier , A. C. Cobos Cerutti , A. Coppolecchia , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. García , M. E. García Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gómez Berisso , M. González , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versillé , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , L. Lamagna , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , M. McCulloch , D. Melo , L. Montier , L. Mousset , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , G. Pisano , M. Platino , G. Polenta , D. Prêle , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , C. G. Scóccola , S. Scully , S. Spinelli , G. Stankowiak , M. Stolpovskiy , A. D. Supanitsky , P. Timbie , M. Tomasi , G. Tucker , C. Tucker , D. Viganò , N. Vittorio , F. Wicek , M. Wright , A. Zullo

Taking advantage of the advances in array detector technology, an imaging polarimeter (IMPOL) has been constructed for measuring linear polarization in the wavelength band from 400-800 nm. It makes use of a Wollaston prism as the analyser…

天体物理学 · 物理学 2009-09-15 A. N. Ramaprakash , Ranjan Gupta , A. K. Sen , S. N. Tandon

We describe the design of a cryogenic rotation stage (CRS) for use with the cryogenic half-wave plate (CHWP) polarization modulator on the POLARBEAR-2b and POLARBEAR-2c (PB2b/c) cosmic microwave background (CMB) experiments, the second and…

The most accessible method to measure polarization features of the CMB radiation is by means of a Stokes Polarimeter based on the rotation of an Half Wave Plate. The current observational cosmology is starting to be limited by the presence…

天体物理仪器与方法 · 物理学 2019-07-24 G. D'Alessandro , L. Mele , F. Columbro , L. Pagano , F. Piacentini , P. de Bernardis , S. Masi

A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact…

We have built and tested a compact, low-cost, but very-high-performance astronomical polarimeter based on a continuously rotating half-wave plate and a high-speed imaging detector. The polarimeter is suitable for small telescopes up to ~1 m…

天体物理仪器与方法 · 物理学 2023-02-08 Jeremy Bailey , Daniel V. Cotton , Ain De Horta , Lucyna Kedziora-Chudczer , Om Shastri

This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error…

A shearing interferometer is presented which uses polarization control to shear the wavefront and to modulate the interference pattern. The shear is generated by spatial walk-off in a birefringent crystal. By adjusting the orientation of…

光学 · 物理学 2012-12-11 Peter Beyersdorf , Mark Cordier

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

天体物理仪器与方法 · 物理学 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

The polarimetry of the light scattered by planetary surfaces is a powerful tool to provide constraints on their microstructure. To improve the interpretation of polarimetric data from icy surfaces, we have developed the POLarimeter for ICE…

地球与行星天体物理 · 物理学 2018-09-25 Olivier Poch , Romain Cerubini , Antoine Pommerol , Bernhard Jost , Nicolas Thomas

We present the on-site rotation performance of the first three cryogenic continuously rotating half-wave plate (HWP) polarization modulators for the Simons Observatory small aperture telescopes (SATs). The SATs operate at an altitude of…

‹ 上一页 1 2 3 10 下一页 ›