相关论文: Status of the ILC Main Linac BPM R&D
Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has…
We report on recent progress in the design of the proposed MATHUSLA Long Lived Particle (LLP) detector for the HL-LHC, updating the information in the original Letter of Intent (LoI), see CDS:LHCC-I-031, arXiv:1811.00927. A suitable site…
The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…
A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised…
Collimator wakefields in the Beam Delivery System (BDS) of future linear colliders, such as the International Linear Collider (ILC) and the Compact Linear Collider (CLIC), can be an important source of emittance growth and beam jitter…
Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the…
A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without…
Integrated sensing and communication (ISAC) is a promising paradigm for future wireless systems due to spectrum reuse, hardware sharing, and joint waveform design. In dynamic scenes, Doppler shifts degrade both sensing and communication,…
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques…
For the CLIC two-beam scheme, a high-current, long-pulse drive beam is required for RF power generation. Taking advantage of the 3 GHz klystrons available at the LEP injector once LEP stops, a 180 MeV electron accelerator is being…
The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
In this paper, an iterative interference cancellation (IIC) based BICM-ID receiver is designed to cancel the intrinsic interference in FBMC-QAM systems. The proposed receiver consist of an inner decoder, which combines iterative…
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…
Beam loss (BLM) and beam current monitors (BCM) are ubiquitous at particle accelerator around the world. These simple devices provide non-invasive high level beam measurements, but give no insight into the detailed 6D (x,y,z,px,py,pz) beam…
A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…
The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…
In order to fully exploit the physics potential of the ILC, it will be necessary to measure (and control) beam parameters to a permille level precision. In case of the beam polarisation, this can only be achieved with dedicated high energy…
Highly integrated multichannel readout electronics is crucial in contemporary particle physics experiments. A novel silicon photomultiplier readout system based on the VMM3a ASIC was developed, for the first time exploiting this chip for…
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve…