用于空间应用且在低温以上温度工作的Si(Li)探测器的钝化

天体物理仪器与方法 2021-02-12 v1 仪器与探测器

摘要

本工作评估了聚酰亚胺和parylene-C用于锂漂移硅(Si(Li))探测器钝化的可行性。钝化的Si(Li)探测器将构成General Antiparticle Spectrometer (GAPS)实验的粒子追踪器和X射线探测器,该气球载实验经过优化以探测暗物质湮灭或衰变产生的宇宙反氘核。通过热固化聚酰亚胺实现了成功的钝化涂层,且优化后的涂层对湿度和有机污染形成优异屏障。钝化的Si(Li)探测器在 -35 至 45-45\,^{\circ}C 温度下工作时,对20-100 keV X射线提供 4\lesssim\,4 keV 能量分辨率(FWHM)。这是首次报道的在低温以上温度工作的基于Si(Li)的X射线探测器成功钝化。