摘要
我们为一种使用光电倍增管读出钨酸铅晶体的电磁量热仪,开发了一种基于蓝光和红光发光二极管并耦合到由光纤组成的分配网络的高稳定性监测系统。我们报告了该系统原型的设计以及实验室测试的结果。在原型运行一周期间,实现了优于0.1%(均方根)的稳定性。
引用
@article{arxiv.physics/0509233,
title = {Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter},
author = {V. A. Batarin and J. Butler and A. M. Davidenko and A. A. Derevschikov and Y. M. Goncharenko and V. N. Grishin and V. A. Kachanov and V. Y. Khodyrev and A. S. Konstantinov and V. A. Kormilitsin and V. I. Kravtsov and Y. Kubota and V. S. Lukanin and Y. A. Matulenko and Y. M. Melnick and A. P. Meschanin and N. E. Mikhalin and N. G. Minaev and V. V. Mochalov and D. A. Morozov and L. V. Nogach and A. V. Ryazantsev and P. A. Semenov and V. K. Semenov and K. E. Shestermanov and L. F. Soloviev and S. Stone and A. V. Uzunian and A. N. Vasiliev and A. E. Yakutin and J. Yarba},
journal= {arXiv preprint arXiv:physics/0509233},
year = {2016}
}
备注
10 pages, 6 figures, LaTeX2e