English
Related papers

Related papers: Silicon Drift Detector Readout Electronics for a C…

200 papers

The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…

Instrumentation and Detectors · Physics 2019-09-04 Mathieu Benoit

Physical principles of performance and main characteristics of a novel avalanche photodetector developed on the basis of MOS(metal-oxide-silicon) technology is presented. The photodetector contains a semitransparent gate electrode and a…

High Energy Physics - Experiment · Physics 2007-05-23 Z. Ya. Sadygov , M. K. Suleimanov , T. Yu. Bokova

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking…

A detector concept based on hybrid planar pixel-detector technology is under development for the CLIC vertex detector. It comprises fast, low-power and small-pitch readout ASICs implemented in 65 nm CMOS technology (CLICpix) coupled to…

Instrumentation and Detectors · Physics 2015-06-18 Dominik Dannheim

CLICTD is a monolithic silicon pixel sensor fabricated in a modified 180 nm CMOS imaging process with a small collection electrode design and a high-resistivity epitaxial layer. It features an innovative sub-pixel segmentation scheme and is…

Instrumentation and Detectors · Physics 2020-11-19 Katharina Dort

Electron spins in silicon quantum dots provide a promising route towards realising the large number of coupled qubits required for a useful quantum processor. At present, the requisite single-shot spin qubit measurements are performed using…

A possible implementation of the Micro Drift Chamber (MDC) technique as a high resolution vertex detector in the upstream part of the DIRAC spectrometer was investigated in this paper. Simulations of different MDC layout were performed with…

Instrumentation and Detectors · Physics 2008-05-16 A. Dudarev , V. Kruglov , L. Kruglova , M. Nikitin

The SIDDHARTA-2 experiment at the DA$\Phi$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon…

Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of…

Instrumentation and Detectors · Physics 2016-11-15 Oliver Kortner , Hubert Kroha , Felix Müller , Sebastian Nowak , Robert Richter

We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…

New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data…

Instrumentation and Detectors · Physics 2022-11-23 Yuxiang Guo , Xueye Hu , Thomas Schwarz , Bing Zhou , Junjie Zhu

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the…

Instrumentation and Detectors · Physics 2019-08-14 C. Schill

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle…

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper…

Instrumentation and Methods for Astrophysics · Physics 2015-05-28 Guillermo Fernandez Moroni , Juan Estrada , Eduardo E. Paolini , Gustavo Cancelo , Stephen E. Holland , H. Thomas Diehl

The ePIC collaboration is developing a multidetector system to explore the fundamental properties of the strong interaction at the future Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory. A key component of the…

Instrumentation and Detectors · Physics 2026-01-15 R. Turrisi

A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT…

Astrophysics · Physics 2009-11-07 H. Tajima , T. Kamae , S. Uno , T. Nakamoto , Y. Fukazawa , T. Mitani , T. Takahashi , K. Nakazawa , Y. Oakada , M. Nomachi

We demonstrate a prototype kinetic inductance detector (KID) readout system that uses less than 10 mW per pixel. The CCAT-prime RFSoC based readout is capable of reading four independent detector networks of up to 1000 KIDs each. The power…

Instrumentation and Methods for Astrophysics · Physics 2023-05-02 Adrian K. Sinclair , James R. Burgoyne , Yaqiong Li , Cody Duell , Scott C. Chapman , Anthony I. Huber , Ruixuan Xie

An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $\gamma$ rays. We report detailed measurements of low-energy spectra from Compton…

Instrumentation and Detectors · Physics 2017-08-30 K. Ramanathan , A. Kavner , A. E. Chavarria , P. Privitera , D. Amidei , T. -L. Chou , A. Matalon , R. Thomas , J. Estrada , J. Tiffenberg , J. Molina

A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25…