Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of expected rates at future high-energy hadron colliders. Results show that it fulfills the requirements over most of the acceptance of muon detectors. The optimization of the read-out electronics to further increase the rate capability of the detectors is discussed. Chambers of this type are under construction for upgrades of the muon spectrometer of the ATLAS detector at high LHC luminosities. Design and construction procedures have been optimized for mass production while providing a precision of better than 10 micrometers in the sense wire positions and the mechanical stability required to cover large areas.

Keywords

Cite

@article{arxiv.1511.09204,
  title  = {Precision Muon Tracking at Future Hadron Colliders with sMDT Chambers},
  author = {Oliver Kortner and Hubert Kroha and Felix Müller and Sebastian Nowak and Robert Richter},
  journal= {arXiv preprint arXiv:1511.09204},
  year   = {2016}
}

Comments

5 pages, 12 figures; conference proceedings for IEEE NSS & MIC conference, San Diego, 2015