Studies of a single photon counting hybrid pixel detector for X-ray imaging applications are presented. A silicon- and a CdTe-sensor were bump bonded onto the MPEC pixel readout chip and could be successfully operated. A new USB based…

High Energy Physics - Experiment · Physics 2007-05-23 P. Fischer , M. Kouda , S. Krimmel , H. Krueger , M. Lindner , M. Loecker , G. Sato , T. Takahashi , S. Watanabe , N. Wermes

Sensitive charge detection has enabled qubit readout in solid-state systems. Recently, an alternative to the well-established charge detection via on-chip electrometers has emerged, based on in situ gate detectors and radio-frequency…

Mesoscale and Nanoscale Physics · Physics 2017-05-24 A. Rossi , R. Zhao , A. S. Dzurak , M. F. Gonzalez-Zalba

Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large…

Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest…

Instrumentation and Detectors · Physics 2025-10-22 T. Muscheid , R. Gartmann , N. Karcher , F. Schuderer , M. Neidig , L. E. Ardila-Perez , M. Balzer , S. Kempf , O. Sander

A new silicon-strip readout chip named "SliT" has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal…

For large scale applications, hybrid pixel detectors, in which sensor and read-out IC are separate entities, constitute the state of the art in pixel detector technology to date. They have been developed and start to be used as tracking…

Instrumentation and Detectors · Physics 2010-01-22 Norbert Wermes

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller…

Instrumentation and Detectors · Physics 2014-10-27 J. Yoo , H. Cease , W. F. Jaskierny , D. Markley , R. B. Pahlka , D. Balakishiyeva , T. Saab , M. Filipenko

We report on progress in the development of the LSTFE2 prototype front-end ASIC geared towards the readout of silicon microstrip sensors in a Linear Collider detector. We also discuss progress in the design of the back-end digital…

Instrumentation and Detectors · Physics 2007-05-23 Jurgen Kroseberg , Alex Grillo , Forest Martinez-McKinney , Gavin Nesom , Bruce A. Schumm , Ned Spencer , Max Wilder

'EPECUR' experiment setup is under construction at the beam line 322 of the ITEP proton synchrotron. The experiment requires several large area drift chambers to provide reasonable acceptance and fine pitch proportional chambers for beam…

There is a growing interest in the science uniquely enabled by observations in the MeV range, particularly in light of multi-messenger astrophysics. The Compton Pair (ComPair) telescope, a prototype of the AMEGO Probe-class concept,…

One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been…

Single-photon imaging spectrometers of high quantum efficiency in the infrared to ultraviolet wavelength range, with good timing resolution and with a vanishing dark count rate are on top of the wish list in earth-bound astronomy, material…

Instrumentation and Detectors · Physics 2007-06-13 Miha Furlan , Eugenie Kirk , Alex Zehnder

The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come…

The development of CMOS pixel sensors with column parallel read-out and integrated zero-suppression has resulted in a full size, nearly 1 Megapixel, prototype with ~100 \mu s read-out time. Its performances are quite close to the ILD vertex…

Instrumentation and Detectors · Physics 2010-07-16 Christine Hu-Guo , IPHC Collaboration , IRFU Collaboration

Silicon microstrip detectors are widely used in experiments for space astronomy. Before the detector is assembled, extensive characterization of the silicon microstrip sensors is indispensable and challenging. This work electrically…

Instrumentation and Detectors · Physics 2021-03-29 Jia-Ju Wei , Jian-Hua Guo , Yi-Ming Hu

A new TDC-chip is under development for the COMPASS experiment at CERN. The ASIC, which exploits the 0.6 micrometer CMOS sea-of-gate technology, will allow high resolution time measurements with digitization of 75 ps, and an unprecedented…

High Energy Physics - Experiment · Physics 2007-05-23 G. Braun , H. Fischer , J. Franz , A. Grunemaier , F. H. Heinsius , K. Konigsmann , M. Schierloh , T. Schmidt , H. Schmitt , H. J. Urban

We demonstrate the design of an integrated conditional quantum teleportation circuit and a readout circuit using a two-dimensional photonic crystal single chip. Fabrication and testing of the proposed quantum circuit can be accomplished…

Quantum Physics · Physics 2015-06-26 Durdu Ö. Güney , David A. Meyer

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light…

Instrumentation and Detectors · Physics 2022-09-28 V. Cianciolo , Yu. V. Efremenko , L. Fabris , S. K. Imam , S. I. Penttila J. C. Ramsey , R. Santos Estrada

The electronics of the CMS Drift Tube (DT) chambers need to be replaced during Long Shutdown 3 to tolerate the High Luminosity LHC (HL-LHC) data taking conditions. The first DT prototypes of the HL-LHC electronics, the on-detector board…

Instrumentation and Detectors · Physics 2021-10-29 Barbara Alvarez Gonzalez

Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the…

Medical Physics · Physics 2022-06-10 Fredrik Grönberg , Zhye Yin , Jonathan Maltz , Norbert J. Pelc , Mats Persson