English
Related papers

Related papers: Breaking the 10 mW/pixel Limit for Kinetic Inducta…

200 papers

We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as…

We describe a kinetic inductance traveling-wave (KIT) amplifier suitable for superconducting quantum information measurements and characterize its wideband scattering and noise properties. We use mechanical microwave switches to calibrate…

We present a high-sensitivity microwave vector detection system for studying the low-dimensional electron system embedded in the gaps of a coplanar waveguide at low temperatures. Using this system, we have achieved 0.005% and…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 W. H. Hsieh , C. H. Kuan , Y. W. Suen , S. Y. Chang , L. C. Li B. C. Lee , C. P. Lee

We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron…

Instrumentation and Detectors · Physics 2008-11-26 A. Bamberger , K. Desch , U. Renz , M. Titov , N. Vlasov , P. Wienemann , A. Zwerger

Astronomical Kinetic Inductance Detectors (KIDs), similar to quantum information devices, experience performance limiting noise from materials. In particular, 1/f (frequency) noise can be a dominant noise mechanism, which arises from…

Superconductivity · Physics 2023-12-14 N. Foroozani , B. Sarabi , S. H. Moseley , T. Stevenson , E. J. Wollack , O. Noroozian , K. D. Osborn

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…

Instrumentation and Methods for Astrophysics · Physics 2025-04-30 Kenneth W. Lin , Abby Bault , Armin Karcher , Julien Guy , Stephen E. Holland , William F. Kolbe , Peter E. Nugent

This paper presents a fast impedance measurement IC for large-scale piezo-resistive sensor array. It features a unified differential time-to-digital demodulation architecture that readout impedance directly through the excitation circuit.…

Systems and Control · Electrical Eng. & Systems 2025-12-01 Jiayang Li , Qingyu Zhang , Sohmyung Ha , Andreas Demosthenous , Dai Jiang , Yu Wu

The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three…

Instrumentation and Methods for Astrophysics · Physics 2016-12-21 O. Bourrion , A. Benoit , J. L. Bouly , J. Bouvier , G. Bosson , M. Calvo , A. Catalano , J. Goupy , C. Li , J. F. Macías-Pérez , A. Monfardini , D. Tourres , N. Ponchant , C. Vescovi

We demonstrate a qubit-readout architecture where the dispersive coupling is entirely mediated by a kinetic inductance. This allows us to engineer the dispersive shift of the readout resonator independent of the qubit and resonator…

The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800…

We report initial results from the design and evaluation of two pixellated PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The prototype imaging PIN detectors consist of 4X4 1.5 mm square indium anode contacts with…

Astrophysics · Physics 2015-06-24 T. Narita , P. Bloser , J. Grindlay , R. Sudharsanan , C. Reiche , C. Stenstrom

We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout…

Instrumentation and Detectors · Physics 2020-09-02 Tenyo Kawamura , Tadashi Orita , Shin'ichiro Takeda , Shin Watanabe , Hirokazu Ikeda , Tadayuki Takahashi

Resistive Silicon Detectors (RSD, also known as AC-LGAD) are innovative silicon sensors, based on the LGAD technology, characterized by a continuous gain layer that spreads across the whole sensor active area. RSDs are very promising…

Instrumentation and Detectors · Physics 2022-09-07 F. Siviero , F. Giobergia , L. Menzio , F. Miserocchi , M. Tornago , R. Arcidiacono , N. Cartiglia , M. Costa , M. Ferrero , G. Gioachin , M. Mandurrino , V. Sola

Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency…

Instrumentation and Detectors · Physics 2012-06-27 Omid Noroozian , Jiansong Gao , Jonas Zmuidzinas , Henry G. LeDuc , Benjamin A. Mazin

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however, silicon suffers from its low atomic number, which might…

Instrumentation and Detectors · Physics 2021-01-26 Moa Yveborg , Cheng Xu , Erik Fredenberg , Mats Danielsson

We report on the fabrication and characterization of single-photon-sensitive WSi superconducting detectors with wire widths from 1 {\mu}m to 3 {\mu}m. The devices achieve saturated internal detection efficiency at 1.55 {\mu}m wavelength and…

This paper presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 keV and 100 keV electrons. The point spread function is measured to be (13.0+/- 1.7) microns at 100 keV and…

Instrumentation and Detectors · Physics 2009-06-25 Marco Battaglia , Devis Contarato , Peter Denes , Dionisio Doering , Velimir Radmilovic

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout…

Instrumentation and Detectors · Physics 2009-01-23 Yosuke Takubo , Hirokazu Ikeda , Kennosuke Itagaki , Akiya Miyamoto , Tadashi Nagamine , Yasuhiro Sugimoto , Hitoshi Yamamoto