English
Related papers

Related papers: A two-dimensional position-sensitive microchannel …

200 papers

We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different…

Instrumentation and Detectors · Physics 2025-12-03 S. Korpar , R. Dolenec , F. Grijalva , A. Lozar , A. Kodrič , P. Križan , S. Parashari , R. Pestotnik , A. Seljak , D. Žontar

In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS detector was employed as the benchmark detector, the TOF spectra of these two detectors were simultaneously…

Instrumentation and Detectors · Physics 2017-02-08 Yiming Wang , Yigang Yang , Ren Liu

In this letter, a new approach to perform edge detection is presented using an all-dielectric CMOS-compatible metasurface. The design is based on guided-mode resonance which provides a high quality factor resonance to make the edge…

Microchannel plates (MCP) are the basis for many spatially-resolved single-particle detectors such as ICCD or I-sCMOS cameras employing image intensifiers (II), MCPs with delay-line anodes for the detection of cold gas particles or…

Instrumentation and Detectors · Physics 2018-09-27 Michał Lipka , Michał Parniak , Wojciech Wasilewski

We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 micron apertures, crossed by 25 micron anode strips to which it is attached by 50 micron kapton spacers. In the region where…

High Energy Physics - Experiment · Physics 2009-10-31 B. Adeva , F. Gomez , A. Pazos , R. Pfau , M. Plo , J. M. Rodriguez , P. Vazquez , J. C. Labbe

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

Instrumentation and Detectors · Physics 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

Full size single-sided GaAs microstrip detectors with integrated coupling capacitors and bias resistors have been fabricated on 3'' substrate wafers. PECVD deposited SiO_2 and SiO_2/Si_3N_4 layers were used to provide coupling capacitaces…

Instrumentation and Detectors · Physics 2009-10-30 R. Irsigler , R. Geppert , R. Goeppert , M. Hornung , J. Ludwig , M. Rogalla , K. Runge , Th. Schmid , A. Soldner-Rembold , M. Webel , C. Weber

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…

A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…

We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing…

Instrumentation and Detectors · Physics 2009-11-13 O. Jagutzki , V. Dangendorf , R. Lauck , A. Czasch , J. Milnes

We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" $\times$ 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a…

The characterization of individual nanoparticles in a liquid constitutes a critical challenge for environmental, material, and biological sciences. To detect nanoparticles, electronic approaches are especially desirable owing to their…

3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…

Instrumentation and Detectors · Physics 2023-07-19 Kensuke Yamamoto , Sei Ban , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi

We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche…

Instrumentation and Detectors · Physics 2015-06-26 C. Iacobaeus , T. Francke , B. Lund-Jensen , J. Ostling , P. Pavlopoulos , V. Peskov , F. Tokanai

Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…

Instrumentation and Detectors · Physics 2017-04-05 S Potashev , Yu Burmistrov , A Drachev , S Karaevsky , E Konobeevski , S Zuyev

Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution,…

The $\mu$-RWELL is a single-amplification stage resistive Micro-Pattern Gaseous Detector (MPGD). The detector amplification element is realized with a single copper-clad polyimide foil micro-patterned with a blind hole (well) matrix and…

Instrumentation and Detectors · Physics 2019-09-04 G. Bencivenni , R. de Oliveira , G. Felici , M. Gatta , M. Giovannetti , G. Morello , A. Ochi , M. Poli Lener , E. Tskhadadze