English
Related papers

Related papers: A two-dimensional position-sensitive microchannel …

200 papers

We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ…

Instrumentation and Detectors · Physics 2016-09-06 Xu-Dong Ju , Ming-Yi Dong , Chuan-Xing Zhou , Jing Dong , Yu-Bin Zhao , Hong-Yu Zhang , Hui-Rong Qi , Qun Ou-Yang

A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, which has a sensitive area of 80 mm$\times$80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and…

Instrumentation and Detectors · Physics 2015-06-16 Shu-Wen Tang , Peng Ma , Li-Min Duan , Zhi-Yu Sun , Chen-Gui Lu , He-Run Yang , Rong-Jiang Hu , Wen-Xue Huang , Hu-Shan Xu

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…

Instrumentation and Detectors · Physics 2015-05-18 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the…

Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area…

Instrumentation and Detectors · Physics 2016-04-27 Jingbo Wang , Karen Byrum , Marcel Demarteau , Jeffrey Elam , Anil Mane , Edward May , Robert Wagner , Dean Walters , Junqi Xie , Lei Xia , Huyue Zhao

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and…

Instrumentation and Detectors · Physics 2015-06-22 Tai-Hua Lin , Andreas Düdder , Matthias Schott , Chrysostomos Valderanis , Laura Wehner , Robert Westenberger

A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through…

Instrumentation and Detectors · Physics 2017-11-22 Luca Moleri , Purba Bhattacharya , Artur E. C. Coimbra , Amos Breskin , Shikma Bressler

An X-ray detector will be presented that is the combination of a segmented ionization chamber featuring one-dimensional spatial resolution integrated with an intelligent ADC front-end, multi DSP processing and embedded PC platform. This…

Instrumentation and Detectors · Physics 2010-01-26 Francesco Voltolina , Ralf H. Menk , Sergio Carrato

The development of CdZnTe detectors with an orthogpnal coplanar anode structure has important implications for future astrophysical instrumentation. As electron-only devices, like pixel detectors, coplanar anode strip detectors can be…

Astrophysics · Physics 2009-11-06 M. L. McConnell , L. A. Hamel , J. R. Macri , M. McClish , J. R. Ryan

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The…

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…

Instrumentation and Detectors · Physics 2015-06-04 P. Fonte , E. Nappi , P. Martinengo , R. Oliveira , V. Peskov F. Pietropaolo , P. Picchi

We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…

We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30 - 900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The…

Instrumentation and Detectors · Physics 2022-03-29 A. Apponi , F. Pandolfi , I. Rago , G. Cavoto , C. Mariani , A. Ruocco

The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called…

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position…

Instrumentation and Detectors · Physics 2020-05-28 Y. Uesugi , R. Mori , H. Yamashiro , T. Suehara , T. Yoshioka , K. Kawagoe

Microwave sensors integrated with microfluidic platforms can provide the size and permittivity of single cells and microparticles. Amongst the microwave sensor topologies, the planar arrangement of electrodes is a popular choice owing to…

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento

We report on the construction of a UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard…

Instrumentation and Detectors · Physics 2016-01-20 S. Lupone , S. Damoy , A. Husseen , N. Briand , M. Debiossac , S. Tall , P. Roncin