English
Related papers

Related papers: A two-dimensional position-sensitive microchannel …

200 papers

As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or…

We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…

Instrumentation and Methods for Astrophysics · Physics 2023-12-19 Takahiro Minami , Miho Katsuragawa , Shunsaku Nagasawa , Shin'ichiro Takeda , Shin Watanabe , Yutaka Tsuzuki , Tadayuki Takahashi

In this paper, the authors propose a two-dimensional, wide dynamic range, linear displacement sensor using microwave methods. The microwave sensor circuit employs a cylindrical dielectric resonator proximity coupled to a pair of orthogonal…

Applied Physics · Physics 2023-02-28 Premsai Regalla , A. V. Praveen Kumar

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro

The use of conventional imaging techniques becomes problematic when faced with challenging logistics and confined environments. In particular, such scenarios are not unusual in the field of archaeological and mining explorations as well as…

Instrumentation and Detectors · Physics 2022-02-03 S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat

Design and physical operation principles of new microchannel avalanche photodiode (MC APD) with gain up to 10^5 and linearity range improved an order of magnitude compared to known similar devices. A distinctive feature of the new device is…

Atomically thin films and surfaces exhibit many distinctive two-dimensional electronic properties that are absent in bulk crystals. In situ microscale multi-probe measurements have been utilized as an effective method to identify the…

Applied Physics · Physics 2025-03-27 Tomoyuki Iori , Ryu Yukawa

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle…

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main…

Instrumentation and Detectors · Physics 2009-11-11 P. Fonte , T. Francke , N. Pavlopoulos , V. Peskov , I. Rodionov

We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the…

Instrumentation and Methods for Astrophysics · Physics 2012-06-12 D. C. Moore , S. R. Golwala , B. Bumble , B. Cornell , P. K. Day , H. G. LeDuc , J. Zmuidzinas

Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility…

A 2D neutron detector based on 3He convertor and MWPC with an active area of 200 mm \times 200 mm has been successfully designed and fabricated. The detector has been tested with Am/Be neutron source and with collimated neutron beam with…

Instrumentation and Detectors · Physics 2013-05-23 Tian LiChao , Chen YuanBo , Tang Bin , Zhou JianRong , Qi HuiRong , Liu RongGuang , Zhang Jian , Yang GuiAn , Xu Hong , Chen DongFeng , Sun ZhiJia

An advanced technique for a two-dimensional real time visualization of cluster beams in vacuum as well as of the overlap volume of cluster beams with particle accelerator beams is presented. The detection system consists of an array of…

We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…

Instrumentation and Detectors · Physics 2008-11-26 M. Cortesi , R. Alon , R. Chechik , A. Breskin , D. Vartsky , V. Dangendorf

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin

With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions…

We have constructed a microwave detector based on the voltage switching of an underdamped Josephson junction, that is positioned at a current antinode of a {\lambda}/4 coplanar waveguide resonator. By measuring the switching current and the…

Superconductivity · Physics 2017-01-24 G. Oelsner , C. K. Andersen , M. Rehák , M. Schmelz , S. Anders , M. Grajcar , U. Hübner , K. Mølmer , E. Il'ichev