English

GaN Schottky diodes for proton beam monitoring

Instrumentation and Detectors 2018-10-22 v1 Applied Physics

Abstract

We have demonstrated that GaN Schottky diodes can be used for high energy (64.8 MeV) proton detection. Such proton beams are used for tumor treatment, for which accurate and radiation resistant detectors are needed. Schottky diodes have been measured to be highly sensitive to protons, to have a linear response with beam intensity and fast enough for the application. Some photoconductive gain was found in the diode leading to a good compromise between responsivity and response time. The imaging capability of GaN diodes in proton detection is also demonstrated.

Keywords

Cite

@article{arxiv.1810.08377,
  title  = {GaN Schottky diodes for proton beam monitoring},
  author = {Jean-Yves Duboz and Julie Zucchi and Eric Frayssinet and Patrick Chalbet and Sébastien Chenot and Maxime Hugues and Jean-Claude Grini and Richard Trimaud and Marie Vidal and Joël Hérault},
  journal= {arXiv preprint arXiv:1810.08377},
  year   = {2018}
}

Comments

12 pages, 3 figures