相关论文: A Fiber Detector Radiation Hardness Test
Muon tomography is a non-destructive imaging technique that exploits cosmic-ray muons from multiple directions. Its performance critically depends on the stability, active-area coverage, and spatial resolution of position-sensitive…
A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…
The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation…
A coherent, short-length reference arm reflectometer, which utilizes a 76-MHz repetition rate mode-locked fiber laser, was investigated experimentally for long fiber links (> 10 km). The reflectometer combines the advantages of optical…
Results are presented on R&D efforts to design and build large size veto panels, optimized for underground low background experiments, in the most efficient and economical way using commercially available components. A variety of plastic…
We measured the thickness of an insensitive surface layer of a PIN photodiode, Hamamatsu S3590-06, used in the Tokyo Axion Helioscope. We made alpha-particles impinge on the PIN photodiode in various incidence angles and measured the pulse…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
We present a compact scintillating fibre timing detector developed for the Mu3e experiment. Mu3e is one of the flagship experiments of the Swiss particle physics scene, aiming to search for the charged lepton flavour violating…
We report on the initial results of an experiment to determine the effects of proton radiation damage on an X-ray hybrid CMOS detector (HCD). The device was irradiated at the Edwards Accelerator Lab at Ohio University with 8 MeV protons, up…
A silicon photomultiplier (SiPM) array has been developed at FBK-irst having 32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is subdivided into 5 x 22 rectangularly arranged pixels. These sensors are developed to…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
Vertex detectors at future hadron colliders will need to cope with large particle fluences. Diamond is a particularly radiation hard material and exhibits further properties that makes it an attractive material for such detectors. Within…
We describe a complete end-to-end simulation of the response of scintillator counters to charged particles. The counters were extruded with a titanium dioxide surface coating and two channels for the embedded wavelength-shifting fibers…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…
Measurements have been performed of scintillation light intensities emitted from various inorganic scintillators irradiated with low-energy beams of highly-charged ions from an electron beam ion source (EBIS) and an electron cyclotron…
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm…