中文
相关论文

相关论文: A new concept for streamer quenching in resistive …

200 篇论文

The present paper is meant as an update of the presentation given in a previous Resistive Plate Chamber (RPC) workshop, aimed at finding an eco-friendly gas mixture for streamer operation of RPCs. Indeed the streamer working regime is still…

仪器与探测器 · 物理学 2019-09-04 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

仪器与探测器 · 物理学 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End…

仪器与探测器 · 物理学 2017-06-28 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

仪器与探测器 · 物理学 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

仪器与探测器 · 物理学 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…

仪器与探测器 · 物理学 2021-11-30 Yousef Pezeshkian , Amir Kiyoumarsioskouei , Majid Ahmadpouri , Ghasem Ghorbani

The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from…

仪器与探测器 · 物理学 2020-12-30 L. Lopes P. Assis , A. Blanco , P. Fonte , M. Pimenta

A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…

仪器与探测器 · 物理学 2015-05-20 B. Bilki , F. Corriveau , B. Freund , C. Neubüser , Y. Onel , J. Repond , J. Schlereth , L. Xia

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

仪器与探测器 · 物理学 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

Resistive Plate Chambers (RPC) have shown stable operation at the Large Hadron Collider and satisfactory efficiency for the entire Run 1 (2010-2013) and Run 2 (2015-2018) with C$_{2}$H$_{2}$F$_{4}$-based gas mixtures and the addition of…

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Assumed having axial symmetry, the streamer discharge is often described by a fluid model in cylindrical coordinate system, which consists of convection dominated (diffusion) equations with source terms, coupled with a Poisson's equation.…

计算物理 · 物理学 2014-03-27 Chijie Zhuang , Rong Zeng

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

仪器与探测器 · 物理学 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…

仪器与探测器 · 物理学 2021-02-03 Jaydeep Datta , Sridhar Tripathy , Nayana Majumdar , Supratik Mukhopadhyay

The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…

仪器与探测器 · 物理学 2020-12-30 Luca Pizzimento

Resistive electrodes are used in gaseous detectors to quench electrical discharges. This helps to protect delicate electrodes and readout electronics and to improve the stability of the detector operation. An RPWELL is a THGEM-based WELL…

仪器与探测器 · 物理学 2024-06-14 Abhik Jash , Luca Moleri , Andrea Tesi , Shikma Bressler

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…

仪器与探测器 · 物理学 2025-03-10 Giorgia Proto

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

仪器与探测器 · 物理学 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

The transition from a proportional to a self quenching streamer mode, as a function of track length and angle, was investigated in a single wire chamber filled with either pure DME or isobutane. The chamber was irradiated with $^{241}$Am…

仪器与探测器 · 物理学 2009-11-13 Yu. I. Davydov , R. Openshaw
‹ 上一页 1 2 3 10 下一页 ›