相关论文: Accurate measurement of the electron beam polariza…
A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a…
A Compton polarimeter has been installed in Hall A at Jefferson Laboratory. This letter reports on the first electron beam polarization measurements performed during the HAPPEX experiment at an electron energy of 3.3 GeV and an average…
A new Compton longitudinal polarimeter currently under construction for HERA is presented. The key component of the polarimeter is a Fabry-Perot cavity located around the electron beam pipe. With such an optical cavity, a continuous laser…
We have performed a novel comparison between electron-beam polarimeters based on M{\o}ller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $\mu$A) during the $Q_{\rm…
We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was…
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson…
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode,…
For the 1994/95 run of the SLD experiment at SLAC, a Compton polarimeter measured the luminosity-weighted electron beam polarization to be (77.2 +- 0.5)%. This excellent accuracy is achieved by measuring the rate asymmetry of…
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064~nm) beam from a…
We have built a polarimeter in order to measure the electron beam polarization in hall C at JLAB. Using a superconducting solenoid to drive the pure-iron target foil into saturation, and a symmetrical setup to detect the Moller electrons in…
As part of the spin physics program at Jefferson Laboratory (JLab), a M\o ller polarimeter was developed to measure the polarization of electron beam of energies 0.8 to 5.0 GeV. A unique signature for M\o ller scattering is obtained using a…
The backscattering of laser radiation by a relativistic electron beam is a widely used method for measuring the spin polarization of electrons. We consider again the properties of the scattering process paying special attention to recoil…
A Fabry-Perot cavity polarimeter, installed in 2003 at HERA for the second phase of its operation, is described. The cavity polarimeter was designed to measure the longitudinal polarisation of the HERA electron beam with high precision for…
An electron beam polarization of 80% or greater will be a key feature of a 1 TeV Linear Collider. Accurate measurements of the beam polarization will therefore be needed. We discuss design considerations and capabilities for a…
Compton backscattering polarimetry provides a fast and accurate method to measure the polarization of an electron beam in a storage ring. Since the method is non-destructive, the polarization of the electron beam can be monitored during…
This paper discusses the latest progress in the development of GRAPE (Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
Compton backscattering polarimetry provides a fast measurement of the polarization of an electron beam in a storage ring. Since the method is non-destructive, the polarization of the electrons can be monitored during internal target…
The performances of the calorimeter of the Jlab Hall A Compton Polarimeter have been measured using the Mainz tagged photon beam.
The methods to measure the polarization of the x-rays from highly charged heavy ions with a significantly higher accuracy than the existing technology is needed to explore relativistic and quantum electrodynamics (QED) effects including the…