中文
相关论文

相关论文: Validation of the GATE Monte Carlo simulation plat…

200 篇论文

Optical detection of alpha particle emitters in the environment by air radioluminescence is a new technology that enables sensing a radiological threat at safe distances, without putting personnel at risk or contaminating equipment.…

核实验 · 物理学 2023-10-24 Claudia Olaru , Mihail-Razvan Ioan , Mastaneh Zadehrafi

This paper describes the characterization of the GALANTE photometric system, a seven intermediate- and narrow-band filter system with a wavelength coverage from 3000 $\r{A}$ to 9000 $\r{A}$ . We describe the photometric system presenting…

Gate set tomography (GST) provides precise, self-consistent estimates of the noise channels for all of a quantum processor's logic gates. But GST experiments are large, involving many distinct quantum circuits. This has prevented their use…

量子物理 · 物理学 2026-04-08 Corey Ostrove , Kenneth Rudinger , Stefan Seritan , Kevin Young , Robin Blume-Kohout

In this paper we use detailed Monte Carlo simulations to demonstrate that liquid xenon (LXe) can be used to build a Cherenkov-based TOF-PET, with an intrinsic coincidence resolving time (CRT) in the vicinity of 10 ps. This extraordinary…

仪器与探测器 · 物理学 2017-10-11 Juan Jose Gomez-Cadenas , José María Benlloch-Rodríguez , Paola Ferrario

Restricted path integral Monte Carlo simulations are used to calculate the equilibrium properties of hydrogen in the density and temperature range of $9.83 \times 10^{-4}\rm \leq \rho \leq 0.153 \rm gcm^{-3}$ and $5000 \leq T \leq 250 000…

等离子体物理 · 物理学 2009-11-07 B. Militzer , D. M. Ceperley

In this study, the absorbed dose calculation for the cerebral region is refined using the Geant4 software, along with the ROOT and GATE programs. This approach provides a detailed statistical analysis of positron trajectories within a water…

医学物理 · 物理学 2025-05-06 Walter Sabalza-Castillejo , Miguel Martin-Landrove

Physical and biological range uncertainties limit the clinical potential of Proton Beam Therapy (PBT). In this proceedings, we report on two research projects, which we are conducting in parallel and which both tackle the problem of range…

Goupil is a software library designed for the Monte Carlo transport of low-energy gamma-rays, such as those emitted from radioactive isotopes. The library is distributed as a Python module. It implements a dedicated backward sampling…

计算物理 · 物理学 2025-05-20 Valentin Niess , Kinson Vernet , Luca Terray

Transfer learning is a crucial technique for handling a small amount of data that is potentially related to other abundant data. However, most of the existing methods are focused on classification tasks using images and language datasets.…

人工智能 · 计算机科学 2025-06-16 Sung Moon Ko , Sumin Lee , Dae-Woong Jeong , Woohyung Lim , Sehui Han

To build upon the goals of the upcoming INTEGRAL mission, the next generation soft gamma-ray (0.2-20 MeV) observatory will require improved sensitivity to nuclear line emission while maintaining high spectral resolution. We present the…

天体物理学 · 物理学 2007-05-23 Steven E. Boggs , Pierre Jean

The effects of contact geometry and ideality on InGaAs and Si nano-scale n-channel FinFET performance are studied using a quantum-corrected semi-classical Monte Carlo method. Illustrative end, saddle/slot, and raised source/drain contacts…

介观与纳米尺度物理 · 物理学 2019-04-01 Aqyan A. Bhatti , Dax M. Crum , Amith Valsaraj , Leonard F. Register , Sanjay K. Banerjee

We discuss the efficiency of Monte Carlo methods in solving continuum radiative transfer problems. The sampling of the radiation field and convergence of dust temperature calculations in the case of optically thick clouds are both studied.…

天体物理学 · 物理学 2009-11-10 M. Juvela

Purpose: Retinoblastoma (RB) is the most common eye tumor in childhood and can be treated external radiotherapy. The purpose of this work is to evaluate the adequacy of Monte Carlo simulations and the accuracy of a commercial treatment…

医学物理 · 物理学 2018-09-26 L. Brualla , P. A. Mayorga , A. Flühs , A. M. Lallena , J. Sempau , W. Sauerwein

High-resolution optical microscopy suffers from a low contrast in scattering media where a multiply scattered wave obscures a ballistic wave used for image formation. To extend the imaging depth, various gating operations - confocal,…

光学 · 物理学 2018-11-08 Mooseok Jang , Hakseok Ko , Won Kyu Lee , Jae-Seung Lee , Wonshik Choi

This paper presents the simulation of the GLAST high energy gamma-ray telescope. The simulation package, written in C++, is based on the Geant4 toolkit, and it is integrated into a general framework used to process events. A detailed…

The EAGLE instrument for the E-ELT is a multi-IFU spectrograph, that uses a MOAO system for wavefront correction of interesting lines of sight. We present a Monte-Carlo AO simulation package that has been used to model the performace of…

天体物理仪器与方法 · 物理学 2018-08-29 Alastair Basden , Timothy Butterley , Richard Myers

A Monte Carlo model was used to study the scattering error of an absorption meter with a divergent light beam and a limited acceptance angle of the receiver. Reflections at both ends of the tube were taken into account. Calculations of the…

大气与海洋物理 · 物理学 2009-11-06 Jacek Piskozub , Piotr J. Flatau , J. V. R. Zaneveld

A Geant4-based Python/C++ simulation and coding framework, which has been developed and used in order to aid the R&D efforts for thermal neutron detectors at neutron scattering facilities, is described. Built upon configurable geometry and…

A set of physics models for nanodosimetry simulation is being re-engineered for use in Geant4-based simulations. This extension of Geant4 capabilities is part of a larger scale R&D project for multi-scale simulation involving adaptable,…

计算物理 · 物理学 2009-12-10 E. Gargioni , V. Grichine , M. G. Pia
‹ 上一页 1 8 9 10 下一页 ›