相关论文: The CDF MiniPlug Calorimeters at the Tevatron
The performance of the Tevatron collider demonstrated continuous growth over the course of Run II, with the peak luminosity reaching 4\times1032 cm-2 s-1, and the weekly integration rate exceeding 70 pb-1. This report presents a review of…
A summary of the most up-to-date top quark mass measurements at CDF is presented. These analyses use top-antitop candidate events detected in the CDF experiment at the Tevatron collider with an integrated luminosity of up to ~3/fb. The…
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy…
We present the recent results of top-quark physics using up to 6 fb$^{-1}$ of $p \bar p$ collisions at a center of mass energy of $\sqrt s$ = 1.96 TeV analyzed by the CDF collaboration. Thanks to this large data sample, precision top quark…
We summarize some of the the most recent CDF and DO results from the 1992-1995 collider run at the Fermilab Tevatron. These include a detailed examination of the heavy flavor content of W+jet data made by CDF.We found in this study that the…
A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…
Charged particle multiplicities are studied in proton-proton collisions in the forward region at a centre-of-mass energy of $\sqrt{s} = 7\;$TeV with data collected by the LHCb detector. The forward spectrometer allows access to a kinematic…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future…
With the advent of the Tevatron Run 2, the collider experiments, CDF and D0, have reestablished the top quark and the W and Z signals and have begun programs of precision measurements of top quark and electroweak properties. We will survey…
Results on soft and hard diffraction obtained by the CDF Collaboration in Run I of the Fermilab Tevatron pbar-p collider are reviewed and compared with results from the DESY e-p collider HERA and with theoretical expectations. In addition,…
The D0 and CDF detectors at the Fermilab Tevatron have each accumulated more that 9/fb of integrated luminosity. The corresponding large datasets enable the two experiments to perform unprecedented studies of heavy flavor hadron properties.…
In this paper we describe the present status and our plans for the realization of next phases of the CalcPHEP project aimed at the theoretical support of experiments at modern and future accelerators: TEVATRON, LHC, electron Linear…
The consequences of application of new set of criteria, proposed in our previous works, for the improvement of a jet energy calibration accuracy with the process "p~p->photon+jet+X" at Tevatron and for a reduction of background events…
Carbon-tetrafluoride (CF4) is used as a counting gas in particle detectors, but some of its properties that are of interest for large time-projection chambers are not well known. We measure the mean energy, which is proportional to the…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
The physics that can be done with 30 fb$^{-1}$ of data at the Tevatron (TeV33) will significantly advance our understanding of particle physics. In this document we consider the potential of the DO detector for running with the TeV33…