相关论文: An RFQ injection system for the HRIBF
Radio-frequency quadrupole (RFQ) linear accelerators appeared on the accelerator scene in the late 1970s and have since revolutionized the domain of low-energy proton and ion acceleration. The RFQ makes the reliable production of…
A dedicated clinical synchrotron facility for cancer therapy using energetic proton and ion beams (C, He and O) has been designed at GSI for the Radiologische Universitaetsklinik at Heidelberg, Germany. The design of the injector linac is…
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge…
Two efficient and isotope-selective resonant two-photon ionization techniques for loading barium ions into radio-frequency (RF)-traps are demonstrated. The scheme of using a strong dipole-allowed transition at \lambda=553 nm as a first step…
We report on the development of the HEC2 (High Energy Compression and Current) charge breeder, a possible high performance successor to REXEBIS at ISOLDE. The new breeder would match the performance of the HIE-ISOLDE linac upgrade and make…
High-frequency linear accelerators are very suitable for carbon ion therapy, thanks to the reduced operational costs and the high beam quality with respect to synchrotrons, which are presently the only available technology for this…
Intense Highly Charged Ion Beams (HCIB) from injector and charge-breeder ion sources at heavy ion accelerator facilities are in demand to expand research in particle and nuclear physics as well as for radiation effects testing. With current…
The high-intensity proton beam of the TRIUMF 500 MeV cyclotron offers unique opportunities to produce rare isotopes by irradiating a variety of targets. In particular, the ISAC (Isotope Separation and ACceleration) facility provides the…
The ISAC 35 MHz RFQ is designed to accelerate ions of A/q up to 30 from 2keV/u to 150keV/u in cw mode. The RFQ structure is 8 meters long and the vane-shaped rods are supported by 19 rings spaced 40 cm apart. An unusual feature of the…
An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is…
A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field…
We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling…
A 52MHz Radio Frequency Quadrupole (RFQ) linear accelerator (linac) is designed to serve as an initial structure for the SSC-linac system (injector into Separated Sector Cyclotron). The designed injection and output energy are 3.5 keV/u and…
This paper describes a design for the front end of a superconducting (SC) ion linac which can accept and simultaneously accelerate two charge states of uranium from an ECR ion source. This mode of operation increases the beam current…
The Radio-Frequency Quadrupole (RFQ) linac that will accelerate a 20mA proton beam from 50keV to 3MeV has been designed and is being fabricated as the first phase, KOMAC Test Facility (KTF), of the Korea Multipurpose Accelerator Complex…
Femtosecond multiphoton pump-probe photoionization is applied to helium nanodroplets doped with rubidium (Rb). The yield of Rb+ ions features pronounced quantum interference (QI) fringes demonstrating the coherence of a superposition of…
A very intense gamma beam of the Gamma Factory facility proposed at CERN can be used to generate radioactive ion beams (RIBs) with high production yields and study the structure of exotic neutron-rich nuclei. The radioactive nuclides are…
Hot cavity resonant ionization laser ion sources (RILIS) provide a multitude of radioactive ion beams with high ionization efficiency and element selective ionization. However, in hot cavity RILIS there still remains isobaric contaminations…
A room temperature heavy ion linac has been proposed as a new injector of CSRm (the main Cooler Storage Ring) at HIRFL (Heavy Ion Research Facility in Lanzhou), which is expected to improve the performance of HIRFL. The linac injector can…
A RadioFrequency Quadrupole (RFQ) cooler-buncher system has been developed and implemented in a collinear laser spectroscopy setup. This system is dedicated to convert a continuous ion beam into short bunches, while enhancing beam quality…