相关论文: SLAC's Polarized Electron Source Laser System and …
A precise, accurate, and relatively straightforward in-situ method to measure and control the ellipticity of light resonantly interacting with an atomic vapor is described. The technique can be used to minimize vector light shifts. The…
The ISAC polarized beam facility uses a Ti:Sapphire laser for producing spin-polarized beams of short-lived radioactive isotopes, initially 7Li. The laser power and spectral content must be tightly controlled and monitored. The control…
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle…
An easily constructed and operated polarimeter precisely determines the relative Stokes parameters that characterize the polarization of laser light. The polarimeter is calibrated in situ without removing or realigning its optical elements,…
We consider electron-atom scattering in a circularly polarized laser field at sufficiently high electron energies, permitting to describe the scattering process by the first order Born approximation. Assuming the radiation field has…
The LAMP (Lightweight Asymmetry and Magnetism Probe) X-ray telescope is a mission concept to measure the polarization of X-ray astronomical sources at 250 eV via imaging mirrors that reflect at incidence angles near the polarization angle,…
We studied the $e^+e^- \to h \gamma $ process at the International Linear Collider (ILC) at $\sqrt{s}=250$ GeV, based on the full detector simulation of the International Large Detector (ILD). This process is loop-induced in the Standard…
XL-Calibur is a balloon-borne Compton polarimeter for X-rays in the $\sim$15-80 keV range. Using an X-ray mirror with a 12 m focal length for collecting photons onto a beryllium scattering rod surrounded by CZT detectors, a…
We present a novel approach to precisely synthesize arbitrary polarization states of light with a high modulation bandwidth. Our approach consists of superimposing two laser light fields with the same wavelength, but with opposite circular…
Infrared observations of the Galactic center (GC) provide a unique opportunity to study stellar and bow-shock polarization effects in a dusty environment. The goals of this work are to present new Ks- and Lp-band polarimetry on an…
We present the first measurement of the left-right asymmetry in Bhabha scattering with a polarized electron beam. The effective electron vector and axial vector couplings to the Z0 are extracted from a combined analysis of the polarized…
A major advance in accurate electron beam polarization measurement has been achieved at Jlab Hall A with a Compton polarimeter based on a Fabry-Perot cavity photon beam amplifier. At an electron energy of 4.6 GeV and a beam current of 40…
The experimental test problem of the left-right polarization-dependent lifetime asymmetry is discussed. It shows that the existing experiments cannot demonstrate the lifetime asymmetry to be right or wrong after analyzing the measurements…
Exploiting the manipulation of the SLC electron-beam polarization, we present precise direct measurements of the parity violation parameters A_c and A_b in the Z boson - c quark and Z boson - b quark coupling. Quark/antiquark discrimination…
A pump-probe atomic parity violation (APV) experiment performed in a longitudinal electric field, provides a signal breaking mirror symmetry while preserving the cylindrical symmetry of the set-up. The excited vapor acts on the probe beam…
We theoretically study the influence of laser polarization in inelastic scattering of electrons by hydrogen atoms in the presence of a circularly polarized laser field in the domain of field strengths below $10^{7}$ V/cm and high projectile…
Measurements of parity-violating longitudinal analyzing powers (normalized asymmetries) in polarized proton-proton scattering provide a unique window on the interplay between the weak and strong interactions between and within hadrons.…
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing…
Leakage of diffuse polarized emission into Stokes I caused by the polarized primary beam of the instrument might mimic the spectral structure of the 21-cm signal coming from the epoch of reionization (EoR) making their separation difficult.…
The sensitivity of interferometers with linear polarizers to the CMB E and B mode are variant under the rotation of the polarizer frame, while interferometer with circular polarizers are equally sensitive to E and B mode. We present…