相关论文: Measurement of low-energy antiproton detection eff…
The absolute fluxes of the cosmic-ray antiprotons at solar minimum are measured in the energy range 0.18 to 1.4 GeV, based on 43 events unambiguously detected in BESS '95 data. The resultant energy spectrum appears to be flat below 1 GeV,…
The energy spectrum of cosmic-ray antiprotons has been measured in the range 0.18 to 3.56 GeV, based on 458 antiprotons collected by BESS in recent solar-minimum period. We have detected for the first time a distinctive peak at 2 GeV of…
We measured low energy cosmic-ray proton and helium spectra in the kinetic energy range 0.215 - 21.5 GeV/n at different solar activities during a period from 1997 to 2002. The observations were carried out with the BESS spectrometer…
The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
This paper describes the development of a threshold type aerogel Cherenkov counter with a large sensitive area of 0.6 m$^2$ to be carried onboard the BESS rigidity spectrometer to detect cosmic-ray antiprotons. The design incorporates a…
The best measurement of the cosmic ray positron flux available today was performed by the HEAT balloon experiment more than 10 years ago. Given the limitations in weight and power consumption for balloon experiments, a novel approach was…
The energy spectrum of cosmic-ray antiprotons from 0.17 to 3.5 GeV has been measured using 7886 antiprotons detected by BESS-Polar II during a long-duration flight over Antarctica near solar minimum in December 2007 and January 2008. This…
This thesis discusses two different approaches for the measurement of cosmic-ray antiparticles in the GeV to TeV energy range. The first part of this thesis discusses the prospects of antiparticle flux measurements with the proposed PEBS…
Primary and atmospheric cosmic-ray spectra were precisely measured with the BESS-TeV spectrometer. The spectrometer was upgraded from BESS-98 to achieve seven times higher resolution in momentum measurement. We report absolute fluxes of…
We report cosmic-ray proton and helium spectra in energy ranges of 1 to 120 GeV and 1 to 54 GeV/nucleon, respectively, measured by a balloon flight of the BESS spectrometer in 1998. The magnetic-rigidity of the cosmic-rays was reliably…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the…
This work discusses the prospects of antiparticle flux measurements with the proposed PEBS detector. The project foresees long duration balloon flights at one of Earth's poles at an altitude of 40 km. The sky coverage of flights at the…
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based…
The cosmic-ray proton, helium, and muon spectra at small atmospheric depths of 4.5 -- 28 g/cm^2 were precisely measured during the slow descending period of the BESS-2001 balloon flight. The variation of atmospheric secondary particle…
This article proposes a new method to measure the proton detector efficiency for use in "beam" determinations of the free neutron lifetime. There is currently a 4{\sigma} disagreement between the "beam" and "storage" methods of measuring…
In two long-duration balloon flights over Antarctica, the BESS-Polar collaboration has searched for antihelium in the cosmic radiation with higher sensitivity than any reported investigation. BESS- Polar I flew in 2004, observing for 8.5…
The identification of deuteron with momentum in range of $0.52$-$0.72$ GeV/$c$ has been studied with the specific ionization energy loss information, using the data sample collected by the BESIII detector at center-of-mass energies between…
We design a GeV gamma ray detector based on an electron-positron pair measurement by using the BESS-polar magnet and study it with the GEANT4 simulation code. We consider an additional counter to select an electron-positron pair for which…
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy…