相关论文: Beam Position-Phase Monitors for SNS Linac
Spallation source dedicated for neutron scattering experiments, as well as multi-purpose facilities serving several applications call for pulsed mode operation of a high intensity proton linac. There is general agreement on the…
The KEK 8-GeV electron / 3.5-GeV positron linac has been operated with very different beam specifications for downstream rings, KEKB, PF and PF-AR. For the reliable operation among these beam modes intelligent beam switching and beam…
The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
In order to double the positron injection rate into the KEKB ring, a two-bunch acceleration scheme has been studied at the linac, in which bunches separated by 96 ns are accelerated in 50 Hz. In this scheme the stabilization of energy and…
An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and…
The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally corrected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift…
The injection system of the China Spallation Neutron Source uses H- stripping and phase space painting method to fill large ring acceptance with the linac beam of small emittance. The emittance evolution, beam losses, and collimation…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
The phase characteristics of reflecting and transmitting type twisted nematic liquid crystal based Spatial Light Modulators (SLMs) were measured using interferometry. Device parameters like contrast, brightness, input and output polarizer…
This conceptual design report provides a detailed account of the European Spallation Source neutrino Super Beam (ESS$\nu$SB) feasibility study. This facility has been proposed after the measurements reported in 2012 of a relatively large…
Recording changes in beam transverse positions re-ported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector (orbit response) is a powerful tool for analysis of accelerator optics and assisting…
The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…
Very intense neutrino beams and large neutrino detectors will be needed in order to enable the discovery of CP violation in the leptonic sector. We propose to use the proton linac of the European Spallation Source currently under…
This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with…
The Spallation Neutron Source (SNS) is being designed for operation in 2004. The SNS is a 1 GeV machine consisting of a combination normal-conducting and super-conducting linac as well as a ring and target area. The linac front end is a…
We present a novel method to characterize the e+/- phase space at the IP of the SLAC B-factory, that combines single-beam measurements with a detailed mapping of luminous-region observables. Transverse spot sizes are determined in the two…
The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and…
In this paper we present results of using parallel supercomputers to simulate beam dynamics in next-generation high intensity ion linacs. Our approach uses a three-dimensional space charge calculation with six types of boundary conditions.…
The Pohang Accelerator Laboratory operates an electron linac for the pulsed neutron source as one of the long-term nuclear R&D programs at the Korea Atomic Energy Research Institute. The designed beam parameters are as follows; The nominal…