中文
相关论文

相关论文: Multi-Kernel TOF-PET Image Reconstruction Using AD…

200 篇论文

In positron emission tomography (PET), it is indispensable to perform attenuation correction in order to obtain the quantitatively accurate activity map (tracer distribution) in the body. Generally, this is carried out based on the…

医学物理 · 物理学 2025-10-16 Liyang Hu , Chong Chen

An alternating direction method of multipliers (ADMM) framework is developed for nonsmooth biconvex optimization for inverse problems in imaging. In particular, the simultaneous estimation of activity and attenuation (SAA) problem in…

医学物理 · 物理学 2024-02-13 Zhimei Ren , Emil Y. Sidky , Rina Foygel Barber , Chien-Min Kao , Xiaochuan Pan

The use of Time Of Flight (TOF) in Positron Emission Tomography (PET) is expected to reduce noise on images, thanks to the additional information. In clinical routine, a common reconstruction approach is the use of maximum likelihood…

医学物理 · 物理学 2019-10-16 Luca Presotto , Elisabetta De Bernardi , Valentino Bettinardi

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance…

In this paper, we develop a dual alternating direction method of multipliers (ADMM) for an image decomposition model. In this model, an image is divided into two meaningful components, i.e., a cartoon part and a texture part. The…

图像与视频处理 · 电气工程与系统科学 2024-12-20 Qingsong Wang , Chengjing Wang , Peipei Tang , Dunbiao Niu

We consider X-ray coherent scatter imaging, where the goal is to reconstruct momentum transfer profiles (spectral distributions) at each spatial location from multiplexed measurements of scatter. Each material is characterized by a unique…

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF)…

仪器与探测器 · 物理学 2024-10-17 Minseok Yi , Daehee Lee , Alberto Gola , Stefano Merzi , Michele Penna , Jae Sung Lee , Simon R. Cherry , Sun Il Kwon

In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution,…

PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently deep neural networks have been widely and successfully used in computer vision tasks and attracted…

计算机视觉与模式识别 · 计算机科学 2017-10-11 Kuang Gong , Jiahui Guan , Kyungsang Kim , Xuezhu Zhang , Georges El Fakhri , Jinyi Qi , Quanzheng Li

We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at…

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

仪器与探测器 · 物理学 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly…

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is…

The integration of Time-of-Flight (TOF) information in the reconstruction process of Positron Emission Tomography (PET) yields improved image properties. However, implementing the cutting-edge model-based deep learning methods for TOF-PET…

图像与视频处理 · 电气工程与系统科学 2023-02-22 Chenxu Li , Rui Hu , Jianan Cui , Huafeng Liu

In this paper, we propose two low-complexity peak to average power ratio(PAPR) reduction algorithms for orthogonal frequency division multiplexing(OFDM) signals. The main content is as follows: First, a non-convex optimization model is…

信号处理 · 电气工程与系统科学 2025-09-18 Hao Su , Jiangtao Wang , Yongchao Wang

The ability of widely distributed radar systems to capture diverse spatial scattering properties substantially improves radar imaging performance. Traditional imaging methods leverage regularized optimization techniques to reconstruct…

信号处理 · 电气工程与系统科学 2023-07-18 Ahmed Murtada , Bhavani Shankar Mysore Rama Rao , Udo Schroeder

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

图像与视频处理 · 电气工程与系统科学 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Artificial intelligence (AI) is entering medical imaging, mainly enhancing image reconstruction. Nevertheless, improvements throughout the entire processing, from signal detection to computation, potentially offer significant benefits. This…

机器学习 · 计算机科学 2023-10-27 Stephan Naunheim , Yannick Kuhl , David Schug , Volkmar Schulz , Florian Mueller

Low-count reconstruction remains a challenge for Positron Emission Tomography (PET) even with the recent progress in time-of-flight (TOF) resolution. In this context, the bias between the acquired histogram, consisting of low values or…

医学物理 · 物理学 2023-01-12 Maxime Toussaint , Francis Loignon-Houle , Roger Lecomte , Jean-Pierre Dussault

Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…

‹ 上一页 1 2 3 10 下一页 ›