中文
相关论文

相关论文: SynthRAR: Ring Artifacts Reduction in CT with Unro…

200 篇论文

Inconsistent responses of X-ray detector elements lead to stripe artifacts in the sinogram data, which manifest as ring artifacts in the reconstructed CT images, severely degrading image quality. This paper proposes a method for correcting…

图像与视频处理 · 电气工程与系统科学 2025-07-01 Ligen Shi , Xu Jiang , YunZe Liu , Chang Liu , Ping Yang , Shifeng Guo , Xing Zhao

Ring artifacts are prevalent in 3D cone-beam computed tomography (CBCT) due to non-ideal responses of X-ray detectors, substantially affecting image quality and diagnostic reliability. Existing state-of-the-art (SOTA) ring artifact…

图像与视频处理 · 电气工程与系统科学 2025-11-11 Qing Wu , Hongjiang Wei , Jingyi Yu , Yuyao Zhang

Low performance pixels (LPP) in Computed Tomography (CT) detectors would lead to ring and streak artifacts in the reconstructed images, making them clinically unusable. In recent years, several solutions have been proposed to correct LPP…

计算机视觉与模式识别 · 计算机科学 2026-01-30 Hongxu Yang , Levente Lippenszky , Edina Timko , Lehel Ferenczi , Gopal Avinash

Ring artifacts in computed tomography images, arising from the undesirable responses of detector units, significantly degrade image quality and diagnostic reliability. To address this challenge, we propose a dual-domain regularization model…

图像与视频处理 · 电气工程与系统科学 2024-03-18 Hongyang Zhu , Xin Lu , Yanwei Qin , Xinran Yu , Tianjiao Sun , Yunsong Zhao

X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…

医学物理 · 物理学 2025-05-27 Yang Zou , Meili Qi , Jianhua Zhang , Difei Zhang , Shuwei Wang , Jiale Zhang , Shengkun Yao , Huaidong Jiang

Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…

医学物理 · 物理学 2023-02-03 Dennis Hein , Konstantinos Liappis , Fredrik Grönberg , Alma Eguizabal , Mats Persson

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Ring artifacts are common artifacts in CT imaging, typically caused by inconsistent responses of detector units to X-rays, resulting in stripe artifacts in the projection data. Under circular scanning mode, such artifacts manifest as…

图像与视频处理 · 电气工程与系统科学 2025-04-16 Yunze Liu , Congyi Su , Xing Zhao

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…

图像与视频处理 · 电气工程与系统科学 2020-09-17 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Lei Xing

Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…

图像与视频处理 · 电气工程与系统科学 2024-02-12 Dhruvi Shah , Shruti Mehta , Ashish Agrawal , Shishir Purohit , Bhaskar Chaudhury

This paper proposes a sinogram consistency learning method to deal with beam-hardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent…

医学物理 · 物理学 2019-06-06 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo

In this paper, we propose a sinogram inpainting network (SIN) to solve limited-angle CT reconstruction problem, which is a very challenging ill-posed issue and of great interest for several clinical applications. A common approach to the…

医学物理 · 物理学 2018-11-12 Ji Zhao , Zhiqiang Chen , Li Zhang , Xin Jin

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

图像与视频处理 · 电气工程与系统科学 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

We introduce a new CT image reconstruction algorithm that is less affected by various artifacts. The new reconstruction algorithm is a method of minimizing the difference between synchrotron X-ray tomography data and sinograms generated…

医学物理 · 物理学 2021-11-22 Byung Chun Kim , Hyunju Lee , Kyungtaek Jun

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy…

Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative…

图像与视频处理 · 电气工程与系统科学 2019-06-04 Shabab Bazrafkan , Vincent Van Nieuwenhove , Joris Soons , Jan De Beenhouwer , Jan Sijbers

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo
‹ 上一页 1 2 3 10 下一页 ›