中文
相关论文

相关论文: A comparison of simulation tools for Muon-Induced …

200 篇论文

Proton Induced X-ray Emission (PIXE) using high energy protons is a non destructive multi elemental technique that can analyze medium and heavy trace elements on thick samples. A new experimental setup is being built at the ARRONAX facility…

核实验 · 物理学 2010-11-18 C. Koumeir , F. Haddad , V. Metivier , N. Servagent , N. Michel

Here we study the range of keV positive muons $\mu^+$ implanted in Nb$_2$O$_5$($x$ nm)/Nb($y$ nm)/SiO$_2$(300 nm)/Si [$x$ = 3.6 nm, 3.3 nm; $y$ = 42.0 nm, 60.1 nm] thin films using low-energy muon spin spectroscopy (LE-$\mu$SR). At…

A high-repetition-rate pulsed muon source operating at approximately 50\,kHz holds the potential to improve the sensitivity of various particle physics and material science experiments involving muons. In this article, we propose utilizing…

We report the results of detailed Monte Carlo simulations of the performance expected both at balloon altitudes and at the probable satellite orbit of a hard X-ray coded-aperture camera being developed for the MIRAX mission. Based on a…

天体物理仪器与方法 · 物理学 2016-06-01 Manuel Castro , Joao Braga , Ana Penacchioni , Flavio D'Amico , Rodrigo Sacahui

Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely…

仪器与探测器 · 物理学 2015-06-05 M. Guthoff , O. Brovchenko , W. de Boer , A. Dierlamm , T. Müller , A. Ritter , M. Schmanau , H. -J. Simonis

The Miniaturized Detector for Application in Space (MIDAS) is a compact device with dimensions 5 x 5 x 1 cm3 which combines position sensitive Si detectors and a fast neutrons spectrometer. MIDAS is developed with purpose to act as a linear…

仪器与探测器 · 物理学 2022-02-22 K. Karafasoulis , C. Papadimitropoulos , C. Potiriadis , C. P. Lambropoulos

The SHiP experiment will search for very weakly interacting particles beyond the Standard Model which are produced in a 400 \GeV/$c$ proton beam dump at the CERN SPS. About $10^{11}$ muons per spill will be produced in the dump. To design…

仪器与探测器 · 物理学 2020-01-15 SHiP Collaboration

The low energy muon spin rotation spectroscopy (LE-$\mu$SR) is primarily used to investigate thin films, surfaces, and interfaces of materials, which has matured at the Paul Scherrer Institute (PSI) and is routinely employed by users of the…

仪器与探测器 · 物理学 2023-07-19 X. Ni , L. Zhou , M. M. Martins , Z. Salman , A. Suter , T. Prokscha

The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of…

We give an overview of the SImulation of X-ray TElescopes (SIXTE) software package, a generic, mission-independent Monte Carlo simulation toolkit for X-ray astronomical instrumentation. The package is based on a modular approach for the…

Particle induced X-ray emission (PIXE) is a physical effect that is not yet adequately modelled in Geant4. The current status as in Geant4 9.2 release is reviewed and new developments are described. The capabilities of the software…

计算物理 · 物理学 2015-05-18 M. G. Pia , G. Weidenspointner , M. Augelli , L. Quintieri , P. Saracco , M. Sudhakar , A. Zoglauer

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

医学物理 · 物理学 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

The development of advanced packaging is essential in the semiconductor manufacturing industry. However, non-destructive testing (NDT) of advanced packaging becomes increasingly challenging due to the depth and complexity of the layers…

Masked image modeling (MIM) pre-training for large-scale vision transformers (ViTs) has enabled promising downstream performance on top of the learned self-supervised ViT features. In this paper, we question if the \textit{extremely simple}…

计算机视觉与模式识别 · 计算机科学 2024-05-28 Jin Gao , Shubo Lin , Shaoru Wang , Yutong Kou , Zeming Li , Liang Li , Congxuan Zhang , Xiaoqin Zhang , Yizheng Wang , Weiming Hu

This paper presents the standardization of Proton Induced X-rays Emission (PIXE) technique for the trace element analysis of thick standard samples. Three standard reference materials (SRMs) viz-\`a-vis titanium, copper and iron base alloys…

仪器与探测器 · 物理学 2020-03-10 Johar Zeb , Shad Ali , Muhammad Haneef , Azhar Muhammad Naeem , Jehan Akbar

We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an…

The transport of neutrons in long beamlines at spallation neutron sources presents a unique challenge for Monte-Carlo transport calculations. This is due to the need to accurately model the deep-penetration of high-energy neutrons through…

仪器与探测器 · 物理学 2020-01-07 Douglas D. DiJulio , Isak Svensson , Xiao Xiao Cai , Joakim Cederkall , Phillip M. Bentley

The study of novel quantum materials relies on muon-spin rotation, relaxation, or resonance (\mSR) measurements. Yet, a fundamental limitation persists: many of these materials can only be synthesized in extremely small quantities, often at…

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment…

加速器物理 · 物理学 2021-08-18 The MICE collaboration , M. Bogomilov , R. Tsenov , G. Vankova-Kirilova , Y. P. Song , J. Y. Tang , Z. H. Li , R. Bertoni , M. Bonesini , F. Chignoli , R. Mazza , V. Palladino , A. de Bari , D. Orestano , L. Tortora , Y. Kuno , H. Sakamoto , A. Sato , S. Ishimoto , M. Chung , C. K. Sung , F. Filthaut , M. Fedorov , D. Jokovic , D. Maletic , M. Savic , N. Jovancevic , J. Nikolov , M. Vretenar , S. Ramberger , R. Asfandiyarov , A. Blondel , F. Drielsma , Y. Karadzhov , G. Charnley , N. Collomb , K. Dumbell , A. Gallagher , A. Grant , S. Griffiths , T. Hartnett , B. Martlew , A. Moss , A. Muir , I. Mullacrane , A. Oates , P. Owens , G. Stokes , P. Warburton , C. White , D. Adams , V. Bayliss , J. Boehm , T. W. Bradshaw , C. Brown , M. Courthold , J. Govans , M. Hills , J. -B. Lagrange , C. Macwaters , A. Nichols , R. Preece , S. Ricciardi , C. Rogers , T. Stanley , J. Tarrant , M. Tucker , S. Watson , A. Wilson , R. Bayes , J. C. Nugent , F. J. P. Soler , R. Gamet , P. Cooke , V. J. Blackmore , D. Colling , A. Dobbs , P. Dornan , P. Franchini , C. Hunt , P. B. Jurj , A. Kurup , K. Long , J. Martyniak , S. Middleton , J. Pasternak , M. A. Uchida , J. H. Cobb , C. N. Booth , P. Hodgson , J. Langlands , E. Overton , V. Pec , P. J. Smith , S. Wilbur , G. T. Chatzitheodoridis , A. J. Dick , K. Ronald , C. G. Whyte , A. R. Young , S. Boyd , J. R. Greis , T. Lord , C. Pidcott , I. Taylor , M. Ellis , R. B. S. Gardener , P. Kyberd , J. J. Nebrensky , M. Palmer , H. Witte , D. Adey , A. D. Bross , D. Bowring , P. Hanlet , A. Liu , D. Neuffer , M. Popovic , P. Rubinov , A. DeMello , S. Gourlay , A. Lambert , D. Li , T. Luo , S. Prestemon , S. Virostek , B. Freemire , D. M. Kaplan , T. A. Mohayai , D. Rajaram , P. Snopok , Y. Torun , L. M. Cremaldi , D. A. Sanders , D. J. Summers , L. R. Coney , G. G. Hanson , C. Heidt

The hit response of silicon vertex and tracking detectors to muon collider beam background and results of a study of hit reducing techniques are presented. The background caused by decays of the 750 GeV/c m+ and m- beams was simulated using…

仪器与探测器 · 物理学 2018-09-26 V. Di Benedetto , C. Gatto , A. Mazzacane , N. V. Mokhov , S. I. Striganov , N. K. Terentiev