中文
相关论文

相关论文: Design, construction, and testing of the PandaX-xT…

200 篇论文

PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large…

仪器与探测器 · 物理学 2021-08-11 Li Zhao , Xiangyi Cui , Wenbo Ma , Yingjie Fan , Karl Giboni , Tao Zhang , Jianglai Liu , Xiangdong Ji

The PandaX-30T is a proposed next-generation experiment to study dark matter and neutrinos using a dual-phase time projection chamber with \textasciitilde30 tons of liquid xenon. An innovative xenon handling subsystem of the PandaX-30T, the…

仪器与探测器 · 物理学 2023-06-07 Xiuli Wang , Zhuoqun Lei , Yonglin Ju , Jianglai Liu , Ning Zhou , Yu Chen , Zhou Wang , Xiangyi Cui , Yue Meng , Li Zhao

Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is…

天体物理仪器与方法 · 物理学 2015-06-05 Zhao Li , Karl Ludwig Giboni , Haowei Gong , Xiangdong Ji , Andy Tan

The scale of liquid xenon experiments for rare events searching is expanding, which is planned even to fifty tons level. The detector and distillation tower require a reliable cooling source with large cooling power at liquid xenon…

仪器与探测器 · 物理学 2025-06-13 Tao Zhan , Jianglai Liu , Yang Liu , Weihao Wu , Binbin Yan , Zhou Wang

This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to…

仪器与探测器 · 物理学 2022-07-27 Xinbei Jiang , Li Zhao , Shaobo Wang , Jia Fu , Tianjie Wu , Jianglai Liu

In order to solve the continuous large cooling power supply problem (20 kW) for the radon-removal cryogenic distillation system, which operates at high liquid ffow rate of 856 kg/h (5 LPM) for the dark matter detector PandaX-xT of the…

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the…

In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be…

仪器与探测器 · 物理学 2019-09-24 K. L. Giboni , P. Juyal , E. Aprile , Y. Zhang , J. Naganoma

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

We propose a major upgrade to the existing PandaX-4T experiment in the China Jinping Underground Laboratory. The new experiment, PandaX-xT, will be a multi-ten-tonne liquid xenon, ultra-low background, and general-purpose observatory. The…

In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and…

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber…

仪器与探测器 · 物理学 2022-02-23 N. Ackerman , J. Albert , M. Auger , D. J. Auty , I. Badhrees , P. S. Barbeau , L. Bartoszek , E. Baussan , V. Belov , C. Benitez-Medina , T. Bhatta , M. Breidenbach , T. Brunner , G. F. Cao , W. R. Cen , C. Chambers , B. Cleveland , R. Conley , S. Cook , M. Coon , W. Craddock , A. Craycraft , W. Cree , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , C. G. Davis , J. Davis , S. Delaquis , A. Der Mesrobian-Kabakian , R. deVoe , T. Didberidze , J. Dilling , A. Dobi , A. G. Dolgolenko , M. J. Dolinski , M. Dunford , J. Echevers , L. Espic , W. Fairbank , D. Fairbank , J. Farine , W. Feldmeier , S. Feyzbakhsh , P. Fierlinger , K. Fouts , D. Franco , D. Freytag , D. Fudenberg , P. Gautam , G. Giroux , R. Gornea , K. Graham , G. Gratta , C. Hagemann , C. Hall , K. Hall , G. Haller , E. V. Hansen , C. Hargrove , R. Herbst , S. Herrin , J. Hodgson , M. Hughes , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , A. Johnson , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , F. Leonard , F. LePort , G. S. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , D. Mackay , R. MacLellan , M. Marino , J. -M. Martin , Y. Martin , T. McElroy , K. McFarlane , T. Michel , B. Mong , D. C. Moore , K. Murray , R. Neilson , O. Njoya , O. Nusair , K. O'Sullivan , A. Odian , I. Ostrovskiy , C. Ouellet , A. Piepke , A. Pocar , C. Y. Prescott , K. Pushkin , F. Retiere , A. Rivas , A. L. Robinson , E. Rollin , P. C. Rowson , M. P. Rozo , J. Runge , J. J. Russell , S. Schmidt , A. Schubert , D. Sinclair , K. Skarpaas , S. Slutsky , E. Smith , A. K. Soma , V. Stekhanov , V. Strickland , M. Swift , M. Tarka , J. Todd , T. Tolba , D. Tosi , T. I. Totev , R. Tsang , K. Twelker , B. Veenstra , V. Veeraraghavan , J. -L. Vuilleumier , J. -M. Vuilleumier , M. Wagenpfeil , A. Waite , J. Walton , T. Walton , K. Wamba , J. Watkins , M. Weber , L. J. Wen , U. Wichoski , M. Wittgen , J. Wodin , J. Wood , G. Wrede , S. X. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Ya Zeldovich , T. Ziegler

PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The…

The PandaX-III experiment searches the neutrinoless double beta decay of $^{136}$Xe with a high-pressure xenon gaseous time projection chamber~(TPC). Thermal-bonding Micromegas modules are used for charge collection. Benefitting from the…

仪器与探测器 · 物理学 2023-11-23 Wenming Zhang , Heng Lin , Yuanchun Liu , Ke Han , Kaixiang Ni , Shaobo Wang , Wenchang Zhai

PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500…

The PandaX-III experiment uses a high pressure xenon gas TPC to search for the NLDBD of $^{136}$Xe. The Microbulk Micromegas will be used for charge amplification and readout in order to record both the energy and track of an event with…

仪器与探测器 · 物理学 2020-06-17 Shaobo Wang

This manuscript details the proof-of-concept of a small-scale cryogenic heat pump demonstrator, a technology designed to enable high-flow xenon distillation systems for the removal of $^{222}$Rn in future liquid xenon observatories such as…

仪器与探测器 · 物理学 2026-04-23 P. Schulte , D. Wenz , L. Althueser , R. Braun , V. Hannen , C. Huhmann , D. Koke , Y. -T. Lin , P. Unkhoff , C. Weinheimer

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of…

In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which…

‹ 上一页 1 2 3 10 下一页 ›