相关论文: Optimizing Transmission FLASH Radiotherapy for Lar…
The Free-Electron Laser (FEL) FLASH offers the worldwide still unique capability to study ultrafast processes with high-flux, high-repetition rate XUV and soft X-ray pulses. The vast majority of experiments at FLASH are of pump-probe type.…
Standard 6 megavolt (MV) radiotherapy is limited by source size and secondary electron range to minimum radiological penumbra widths of ~2-3 mm. This study investigates sharper beams via upright radiotherapy with lower energies and extended…
Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material &…
Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an…
When treating moving tumors, the precise delivery of proton therapy by pencil beam scanning (PBS) is challenged by the interplay effect. Although several 4D-optimization methods have been proposed, what is the most beneficial motion…
Laser-driven proton sources have long been developed with an eye on their potential for medical application to radiation therapy. These sources are compact, versatile, and show peculiar characteristics such as extreme instantaneous dose…
The differential sparing of normal tissues relative to tumor control observed at ultra-high dose rates, referred to as the FLASH effect, has recently gained considerable attention. The therapeutic advantages of FLASH radiotherapy are…
Ultra-high dose rate (FLASH) proton planning with only transmission beams (TBs) has limitations in normal tissue sparing. The single-energy spread-out Bragg peaks (SESOBPs) of FLASH dose rate have been demonstrated feasible for proton FLASH…
Purpose: This study explored the feasibility of a streamlined pin-shaped ridge filter (pin-RF) design for single-energy proton FLASH planning. Methods: An inverse planning framework integrated within a TPS was established for FLASH…
Background: Ultra-high-dose-rate (UHDR) radiation therapy has demonstrated promising potential in reducing toxicity to organs-at-risk (OARs). Proton therapy is uniquely positioned to deliver UHDR by leveraging the Bragg peak in conjunction…
In recent years, volumetric modulated arc therapy (VMAT) has been becoming a more and more important radiation technique widely used in clinical application for cancer treatment. One of the key problems in VMAT is treatment plan…
The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR),…
This paper presents the design of a rapid cycling synchrotron (RCS) featuring a longitudinal localized kick driven fast extraction system for three-dimensional (3D) pencil beam scanning (PBS) proton FLASH delivery. The extraction method is…
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based…
Abstract Purpose The complex signal decay during the transient FLASH MRI readout can lead to artifacts in magnitude and phase images. We show that target-driven optimization of individual rf flip angles and phases can realize near-ideal…
Purpose: To provide a fast computational method, based on the proximal graph solver (POGS) - a convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating…
Conventional beam orientation optimization (BOO) algorithms for IMRT assume that the same set of beam angles is used for all treatment fractions. In this paper we present a BOO formulation based on group sparsity that simultaneously…
Reducing proton treatment time improves patient comfort and decreases the risk of error from intra-fractional motion, but must be balanced against clinical goals and treatment plan quality. We formulated the proton treatment planning…
Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging…
Ultra high dose rate electron beams also known as FLASH radiotherapy is becoming of importance in several preclinial cancer treatment studies. However, due to the dose rate used during the irradiation sessions, no real time dose monitoring…