中文
相关论文

相关论文: A highly-compact and ultra-fast homogeneous electr…

200 篇论文

Although inorganic scintillators are widely used in the design of electromagnetic calorimeters for high-energy physics and astrophysics, their crystalline nature and, hence, their lattice orientation are generally neglected in the detector…

Recent studies have shown that the electromagnetic shower induced by a high-energy electron, positron or photon incident along the axis of an oriented crystal develops in a space more compact than the ordinary. On the other hand, the…

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…

This article reports on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises…

仪器与探测器 · 物理学 2026-05-26 A. Somov , V. V. Berdnikov , L. Gan , P. V. Laveen , A. Smith , S. Taylor , H. Voskanyan

We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This…

In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…

Crystals are used as a homogeneous calorimetric medium in many high-energy physics experiments. For some experiments, performance has to be ensured in very difficult operating conditions, like a high radiation environment, very large…

仪器与探测器 · 物理学 2009-11-10 Francesca Nessi-Tedaldi

Scintillating crystals are used for calorimetry in several high-energy physics experiments. For many of them, performance has to be ensured in very difficult operating conditions, like a high radiation environment and large particle fluxes,…

仪器与探测器 · 物理学 2017-08-23 F. Nessi-Tedaldi

Next-generation high-energy electron-positron colliders, operating as Higgs factories, require an unprecedented jet energy resolution for precision measurements of Higgs and Z/W bosons. To address this challenge, a conceptual design is…

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic…

仪器与探测器 · 物理学 2018-05-24 Dmitri Denisov , Strahinja Lukić , Nikolai Mokhov , Sergei Striganov , Predrag Ujić

Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed…

Crystal electromagnetic calorimeters (ECALs) are essential for high-precision measurements of electrons and photons in particle physics experiments. However, the conventional design, in which long crystal bars point radially toward the…

This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle…

The research investigates coherent interactions between sub-GeV electrons and oriented scintillator crystals, leading to enhanced electromagnetic (EM) radiation. Experiments at Mainz Mikrotron (MAMI) involved PWO, BGO, and CsI crystals…

Results are presented of beam tests in which a small electromagnetic calorimeter consisting of lead tungstate crystals was exposed to 50 GeV electrons and pions. This calorimeter was backed up by the DREAM Dual-Readout calorimeter, which…

仪器与探测器 · 物理学 2008-11-26 N. Akchurin

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…

We have observed a significant enhancement in the energy deposition by $25$--$100~\mathrm{GeV}$ photons in a $1~\mathrm{cm}$ thick tungsten crystal oriented along its $\langle 111 \rangle$ lattice axes. At $100~\mathrm{GeV}$, this…

In the context of the ClearMind project, we measured the scintillating properties, as induced from from gamma ray interactions, of today available PbWO4 crystal. We measured scintillation s yields and time constants by measuring the signal…

仪器与探测器 · 物理学 2021-09-01 M. Follin , V. Sharyy , J-P. Bard , M. Korzhik , D. Yvon
‹ 上一页 1 2 3 10 下一页 ›