相关论文: A cryogenic test-mass suspension with flexures ope…
The concept of compressive sensing was recently proposed to significantly reduce the electron dose in scanning transmission electron microscopy (STEM) while still maintaining the main features in the image. Here, an experimental setup based…
In low temperature transport measurements, there is frequently a need to protect a device at cryogenic temperatures from thermal noise originating in warmer parts of the experiment. There are also a wide range of experiments, such as high…
A micro-pressure sensor with an isosceles trapezoidal beam-membrane (ITBM) is proposed in this paper, consisting of a square silicon membrane, four isosceles trapezoidal beams and four piezoresistors.To investigate how the elastic silicon…
We show that fast technical fluctuations of microwave signals can be strongly suppressed by cryogenic resonators. The experiments were carried out with sapphire resonators cooled to approximately 6 K at frequencies around 11 GHz. Each…
This investigation has used flexural test to explore the effects of thermal treatments, i.e., high-temperature and cryogenic environments on the mechanical property of alumina particulate-reinforced Cu metal matrix micro and nanocomposites…
We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory Small Aperture Telescope (SAT). The truss consists of two aluminum 6061 rings…
This paper presents a miniature tension sensor using a photo-reflector, designed for compact tendon-driven grippers and robotic hands. The proposed sensor has a small form factor of 13~mm x 7~mm x 6.5~mm and is capable of measuring tensile…
The operation of an interferometer for gravitational waves detection requires sophisticated feedback controls in many parts of the apparatus. The aim of this lecture is to introduce the types of problems to be faced in this line of…
We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable…
Reflection measurements give access to the complex impedance of a material on a wide frequency range. This is of interest to study the dynamical properties of various materials, for instance disordered superconductors. However reflection…
A shift of paradigm to obtain (sub-)Kelvin environment is currently on-going with the democratization of cryogen-free cryocoolers, boosted by their easy-to-use and continuous operation without the need of liquid helium whose cost and…
Gravitational wave detectors like the Einstein Telescope will be built a few hundred meters under Earth's surface to reduce both direct seismic and Newtonian noise. Underground facilities must be designed to take full advantage of the…
Cryogenic quantum sensing techniques are developing alongside the ever-increasing requirements for noiseless experimental environments. For instance, several groups have isolated internal system vibrations from cold heads in closed-cycle…
We study the mechanism of instability in transition edge sensor (TES) bolometers used for ground based observations of the Cosmic Microwave Background (CMB) at 270GHz. The instability limits the range of useful operating resistances of the…
In the baseline design for advanced LIGO interferometers, the most serious noise source is tiny, dynamically fluctuating bumps and valleys on the faces of the arm-cavity mirrors, caused by random flow of heat in the mirrors' sapphire…
Achieving the demanding sensitivity and bandwidth, envisaged for third generation gravitational wave (GW) observatories, is extremely challenging with a single broadband interferometer. Very high optical powers (Megawatts) are required to…
We have extended the range of the high-pressure optical spectroscopy to the far-infrared region keeping the accuracy of ambient-pressure experiments. The newly-developed method offers a powerful tool for the study of pressure-induced phase…
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for…
Increasing requirements in the sensitivity of interferometric measurements is a common feature of several research fields, from gravitational wave detection to quantum optics. This motivates refined studies of high reflectivity mirrors and…
The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…