相关论文: Two new calibration techniques of lumped-parameter…
Usually, clinicians assess the correct hemodynamic behavior and fetal well-being during the gestational age thanks to their professional expertise, with the support of some indices defined for Doppler fetal waveforms. Although this approach…
Objective: to develop quantitative methods for the clinical interpretation of the ballistocardiogram (BCG). Methods: a closed-loop mathematical model of the cardiovascular system is proposed to theoretically simulate the mechanisms…
Parameter calibration is essential for reducing uncertainty and improving predictive fidelity in physics-based models, yet it is often limited by the high computational cost of model evaluations. Bayesian calibration methods provide a…
In the framework of accurate and efficient segregated schemes for 3D cardiac electromechanics and 0D cardiovascular models, we propose here a novel numerical approach to address the coupled 3D-0D problem introduced in Part I of this…
Parameter estimation and uncertainty quantification are crucial in computational cardiology, as they enable the construction of digital twins that faithfully replicate the behavior of physical patients. Robust and efficient mathematical…
Models of electrical excitation and recovery in the heart have become increasingly detailed, but have yet to be used routinely in the clinical setting to guide personalized intervention in patients. One of the main challenges is calibrating…
In this article, we present a resource-efficient approach for electrocardiogram (ECG) based heartbeat classification using multi-feature fusion and bidirectional long short-term memory (Bi-LSTM). The dataset comprises five original classes…
Electrical analogy (Lumped method) is an easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that…
Identification of model parameters in computer simulations is an important topic in computer experiments. We propose a new method, called the projected kernel calibration method, to estimate these model parameters. The proposed method is…
Mathematical models are essential tools to study how the cardiovascular system maintains homeostasis. The utility of such models is limited by the accuracy of their predictions, which can be determined by uncertainty quantification (UQ). A…
Zero-dimensional cardiovascular models provide a computationally efficient framework for studying global hemodynamic behavior, yet the influence of model complexity on parameter sensitivity remains insufficiently understood. This work…
In the drug discovery process, where experiments can be costly and time-consuming, computational models that predict drug-target interactions are valuable tools to accelerate the development of new therapeutic agents. Estimating the…
In many longitudinal settings, time-varying covariates may not be measured at the same time as responses and are often prone to measurement error. Naive last-observation-carried-forward methods incur estimation biases, and existing…
Calibration parameters in deterministic computer experiments are those attributes that cannot be measured or available in physical experiments. Kennedy and O'Hagan \cite{kennedy2001bayesian} suggested an approach to estimate them by using…
Computational cardiovascular models are promising tools for clinical decision support, particularly in complex conditions, such as intraoperative hypotension (IOH). IOH arises from different mechanisms, making treatment selection…
Accurate estimates of left ventricle elastances based on non-invasive measurements are required for clinical decision-making during treatment of valvular diseases. The present study proposes a parameter discovery approach based on a lumped…
Predictive models that accurately emulate complex scientific processes can achieve exponential speed-ups over numerical simulators or experiments, and at the same time provide surrogates for improving the subsequent analysis. Consequently,…
Combined extracorporeal membrane oxygenation (ECMO) and continuous renal replacement therapy (CRRT) pose complex hemodynamic challenges in intensive care. In this study, a comprehensive lumped parameter model (LPM) is developed to simulate…
Computer models are used to model complex processes in various disciplines. Often, a key source of uncertainty in the behavior of complex computer models is uncertainty due to unknown model input parameters. Statistical computer model…
We provide another look at the statistical calibration problem in computer models. This viewpoint is inspired by two overarching practical considerations of computer models: (i) many computer models are inadequate for perfectly modeling…