中文
相关论文

相关论文: A Dual-domain Regularization Method for Ring Artif…

200 篇论文

X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…

医学物理 · 物理学 2025-05-27 Yang Zou , Meili Qi , Jianhua Zhang , Difei Zhang , Shuwei Wang , Jiale Zhang , Shengkun Yao , Huaidong Jiang

Inconsistent responses of X-ray detector elements lead to stripe artifacts in the sinogram data, which manifest as ring artifacts in the reconstructed CT images, severely degrading image quality. This paper proposes a method for correcting…

图像与视频处理 · 电气工程与系统科学 2025-07-01 Ligen Shi , Xu Jiang , YunZe Liu , Chang Liu , Ping Yang , Shifeng Guo , Xing Zhao

Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed…

计算机视觉与模式识别 · 计算机科学 2026-02-13 Hongxu Yang , Levente Lippenszky , Edina Timko , Gopal Avinash

Ring artifacts are common artifacts in CT imaging, typically caused by inconsistent responses of detector units to X-rays, resulting in stripe artifacts in the projection data. Under circular scanning mode, such artifacts manifest as…

图像与视频处理 · 电气工程与系统科学 2025-04-16 Yunze Liu , Congyi Su , Xing Zhao

We present a pixel-specific, measurement-driven correction that effectively minimizes errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to…

仪器与探测器 · 物理学 2019-06-25 Linda C. P. Croton , Gary Ruben , Kaye S. Morgan , David M. Paganin , Marcus J. Kitchen

Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…

Ring artifacts are prevalent in 3D cone-beam computed tomography (CBCT) due to non-ideal responses of X-ray detectors, substantially affecting image quality and diagnostic reliability. Existing state-of-the-art (SOTA) ring artifact…

图像与视频处理 · 电气工程与系统科学 2025-11-11 Qing Wu , Hongjiang Wei , Jingyi Yu , Yuyao Zhang

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Recent CT Metal Artifacts Reduction (MAR) methods are often based on image-to-image convolutional neural networks for adjustment of corrupted sinograms or images themselves. In this paper, we are exploring the capabilities of a multi-domain…

计算机视觉与模式识别 · 计算机科学 2020-05-12 Artem Pimkin , Alexander Samoylenko , Natalia Antipina , Anna Ovechkina , Andrey Golanov , Alexandra Dalechina , Mikhail Belyaev

Spectral computed tomography has received considerable interest in recent years since spectral measurements contain much richer information about the object of interest. In spectral computed tomography, we are interested in the energy…

Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…

医学物理 · 物理学 2023-02-03 Dennis Hein , Konstantinos Liappis , Fredrik Grönberg , Alma Eguizabal , Mats Persson

High density implants such as metals often lead to serious artifacts in the reconstructed CT images which hampers the accuracy of image based diagnosis and treatment planning. In this paper, we propose a novel wavelet frame based CT image…

医学物理 · 物理学 2017-11-21 Haimiao Zhang , Bin Dong , Baodong Liu

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

计算工程、金融与科学 · 计算机科学 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

Objective: X-ray computed tomography employing sparse projection views has emerged as a contemporary technique to mitigate radiation dose. However, due to the inadequate number of projection views, an analytic reconstruction method…

机器学习 · 计算机科学 2025-01-10 Yoseob Han

Classical methods for X-ray computed tomography are based on the assumption that the X-ray source intensity is known, but in practice, the intensity is measured and hence uncertain. Under normal operating conditions, when the exposure time…

数值分析 · 数学 2017-07-17 Hari Om Aggrawal , Martin Skovgaard Andersen , Sean Rose , Emil Y. Sidky

We introduce a new CT image reconstruction algorithm that is less affected by various artifacts. The new reconstruction algorithm is a method of minimizing the difference between synchrotron X-ray tomography data and sinograms generated…

医学物理 · 物理学 2021-11-22 Byung Chun Kim , Hyunju Lee , Kyungtaek Jun

Ultrasound computed tomography (USCT) holds great promise for breast cancer screening. Waveform inversion-based image reconstruction methods account for higher order diffraction effects and can produce high-resolution USCT images, but are…

医学物理 · 物理学 2017-08-25 Thomas P. Matthews , Kun Wang , Cuiping Li , Neb Duric , Mark A. Anastasio

Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…

图像与视频处理 · 电气工程与系统科学 2024-02-12 Dhruvi Shah , Shruti Mehta , Ashish Agrawal , Shishir Purohit , Bhaskar Chaudhury
‹ 上一页 1 2 3 10 下一页 ›