相关论文: Optimization of a portable liquid scintillation co…
A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by…
The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM)…
The primary motivation for this work is the evaluation of the radon concentration in portable water for human consumption in Bibala, a municipality in Angola, where granitic rocks are common, and contain a high concentration of uranium that…
Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…
A large-volume liquid scintillator can be used as a tracking detector to measure high-energy neutrino events, like atmospheric neutrinos and neutrino beams. The lepton flavor recognition is almost absolute above 1 GeV. The energy resolution…
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid…
PETALO (Positron Emission Tof Apparatus with Liquid xenOn) is a novel concept for positron emission tomography scanners, which uses liquid xenon as a scintillation medium and silicon photomultipliers as a readout. The large scintillation…
PETALO (Positron Emission TOF Apparatus with Liquid xenOn) is a project that uses liquid xenon as a scintillation medium, silicon photomultipliers as a readout and fast electronics to provide a significant improvement in PET-TOF technology.…
Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…
The background caused by radon and its daughters is an important background in the low background liquid scintillator (LS) detectors. The study of the diffusion behaviour of radon in the LS contributes to the analysis of the related…
Development of highly sensitive, portable and low-cost sensors for the evaluation of ethanol content in liquid is particularly important in several process monitoring, from food to pharmaceutical industry. In this respect, here we report on…
We report development of a novel instrument to measure tracer diffusion in water under nano-scale confinement. A direct optical access to the confinement region, where water is confined between a tapered fiber and a flat substrate, is made…
It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…
First observation of liquid xenon scintillation due to alpha-particles and gamma-rays with a large area avalanche photodiode immersed in the liquid is reported. An energy resolution of 10% (FWHM) and a coincidence time resolution of less…
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, has been exposed to the highly collimated and quasi-monoenergetic LICORNE neutron beam at the Institute de…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast…
Proportional scintillation in liquid xenon has a promising application in the field of direct dark matter detection, potentially allowing for simpler, more sensitive detectors. However, knowledge of the basic properties of the phenomenon as…
The aim of this study is to measure the radon mass exhalation rate from common granite building materials used in the East and Northeast part of Portugal. Twelve cubic shaped samples were measured. Nine of them without any coating and three…
The study of the neutron response and n-gamma discrimination for small (18x26x8) mm3 liquid scintillator BC501A (Bicron) detector was carried out by digital charge comparison method. Three ranges of neutron energies were used: uniform…