中文
相关论文

相关论文: Thermal noise calibration of functionalized cantil…

200 篇论文

Atomic force microscopy (AFM) is a powerful tool to investigate interaction forces at the micro and nanoscale. Cantilever stiffness, dimensions and geometry of the tip can be chosen according to the requirements of the specific application,…

应用物理 · 物理学 2020-07-31 M. Chighizola , L. Puricelli , L. Bellon , A. Podestà

The Transient Fluctuation Theorem is used to calibrate an Atomic Force Microscope by measuring the fluctuations of the work performed by a time dependent force applied between a collo{\"i}dal probe and the surface. From this measure one can…

介观与纳米尺度物理 · 物理学 2020-12-02 Samuel Albert , Aubin Archambault , Artyom Petrosyan , Caroline Crauste-Thibierge , Ludovic Bellon , Sergio Ciliberto

The functionalization of an Atomic Force Microscope (AFM) cantilever with a colloidal bead is a widely used technique when the geometry between the probe and the sample must be controlled, particularly in force spectroscopy. But some…

介观与纳米尺度物理 · 物理学 2013-05-09 Justine Laurent , Audrey Steinberger , Ludovic Bellon

Non-invasive thermal noise calibration of both torsional and flexural eigenmodes is performed on numerous cantilevers of 10 different types. We show that for all tipless and short-tipped cantilevers, the ratio of torsional to flexural mode…

材料科学 · 物理学 2018-08-15 Per-Anders Thorén , Riccardo Borgani , Daniel Forchheimer , David B. Haviland

A method to precisely calibrate the oscillation amplitude in Dynamic Scanning Force Microscopy is described. It is experimentally shown that a typical electronics used to process the dynamic motion of the cantilever can be adjusted to…

An electro-mechanical setup for the measurement of AC-forces in a low-temperature tunnelling microscope has been developed, which enables extremely high force resolution. The crosstalk of vibrations onto the tunnelling current is used to…

介观与纳米尺度物理 · 物理学 2016-02-17 Markus Herz , Elke Scheer

A common use for atomic force microscopy is to quantify local forces through tip-sample interactions between the probe tip and a sample surface. The accuracy of these measurements depends on the accuracy to which the cantilever spring…

介观与纳米尺度物理 · 物理学 2021-12-08 Aaron Mascaro , Yoichi Miyahara , Omur E. Dagdeviren , Peter Grutter

Thermal fluctuation of the cantilever position sets a fundamental limit for the precision of any Scanning Force Microscope. In the present work we analyse how these fluctuations limit the determination of the resonance frequency of the…

介观与纳米尺度物理 · 物理学 2010-03-03 J. Colchero , M. Cuenca , J. F. Gonzalez Martinez , J. Abad , E. Palacios-Lidon , J. Abellan

A general analysis of thermal noise in torsion pendulums is presented. The specific case where the torsion angle is kept fixed by electronic feedback is analyzed. This analysis is applied to a recent experiment that employed a torsion…

量子物理 · 物理学 2009-11-10 S. K. Lamoreaux , W. T. Buttler

Atomic force microscopy cantilevers are often, intentionally or not, heated at their extremity. We describe a model to compute the resulting temperature field in the cantilever and in the surrounding fluid on a wide temperature range. In…

统计力学 · 物理学 2021-10-08 Basile Pottier , Ludovic Bellon

Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and…

量子物理 · 物理学 2009-11-13 Hsiang-Chih Chiu , Chia-Cheng Chang , R. Castillo-Garza , F. Chen , U. Mohideen

Measurements of the deflection induced by thermal noise have been performed on a rectangular atomic force microscope cantilever in air. The detection method, based on polarization interferometry, can achieve a resolution of 1E-14 m/rtHz in…

统计力学 · 物理学 2009-11-17 Pierdomenico Paolino , Bruno Tiribilli , Ludovic Bellon

Spontaneous collapse models predict that a weak force noise acts on any mechanical system, as a consequence of the collapse of the wave function. Significant upper limits on the collapse rate have been recently inferred from precision…

量子物理 · 物理学 2017-09-20 A. Vinante , R. Mezzena , P. Falferi , M. Carlesso , A. Bassi

Torsional harmonic cantilevers allow measurement of time varying tip-sample forces in tapping-mode atomic force microscopy. Accuracy of these force measurements is important for quantitative nanomechanical measurements. Here we demonstrate…

仪器与探测器 · 物理学 2008-11-26 Ozgur Sahin

A method is presented for calibrating the higher eigenmodes (resonance modes) of atomic force microscopy cantilevers that can be performed prior to any tip-sample interaction. The method leverages recent efforts in accurately calibrating…

介观与纳米尺度物理 · 物理学 2016-08-03 Aleksander Labuda , Marta Kocun , Tim Walsh , Jieh Meinhold , Tania Proksch , Waiman Meinhold , Martin Lysy , Roger Proksch

We report on the fabrication of sensitive nanotorsional resonators, which can be utilized as magnetometers for investigating the magnetization dynamics in small magnetic elements. The thermo-mechanical noise is calibrated with the resonator…

介观与纳米尺度物理 · 物理学 2012-03-06 Joseph Losby , Jacob A. J. Burgess , Zhu Diao , David C. Fortin , Wayne K. Hiebert , Mark R. Freeman

Oscillators based on levitated particles are promising for the development of ultrasensitive force detectors. The theoretical performance of levitated nanomechanical sensors is usually characterized by the so-called thermal noise limit…

仪器与探测器 · 物理学 2022-03-23 Zhenhai Fu , Shaochong Zhu , Ying Dong , Xingfan Chen , Huizhu Hu , Xiaowen Gao

When measuring quadratic values representative of random fluctuations, such as the thermal noise of Atomic Force Microscopy (AFM) cantilevers, the background measurement noise cannot be averaged to zero. We present a signal processing…

仪器与探测器 · 物理学 2017-03-09 Basile Pottier , Ludovic Bellon

Direct time-varying tip-sample force measurements by torsional harmonic cantilevers facilitate detailed investigations of the cantilever dynamics in tapping-mode atomic force microscopy. Here we report experimental evidence that the…

仪器与探测器 · 物理学 2008-11-26 Ozgur Sahin

Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…

介观与纳米尺度物理 · 物理学 2018-01-10 Corinne E. Isaac , Elizabeth A. Curley , Pamela T. Nasr , Hoang L. Nguyen , John A. Marohn
‹ 上一页 1 2 3 10 下一页 ›