In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data…

最优化与控制 · 数学 2016-11-15 Xiao Li , Anna Scaglione , Tsung-Hui Chang

In this paper, phasor measurement unit (PMU) placement for power grid state estimation under different degrees of observability is studied. Observability degree is the depth of the buses' reachability by the placed PMUs and thus constitutes…

系统与控制 · 计算机科学 2018-06-08 Y. Shi , H. D. Tuan , A. A. Nasir , T. Q. Duong , H. V. Poor

This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…

系统与控制 · 电气工程与系统科学 2020-08-04 Reetam Sen Biswas , Behrouz Azimian , Anamitra Pal

Phasor measurement units (PMUs) are important devices for protection, monitoring, and control of modern power systems. Unlike the supervisory control and data acquisition (SCADA) system which only measure the magnitude, PMUs can provide a…

系统与控制 · 电气工程与系统科学 2021-05-06 Lorena Palmero , Ugur Saritac , Ali Dehghan Chaharabi

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…

系统与控制 · 电气工程与系统科学 2023-04-18 Saptarshi Ghosh , Murali Sankar Venkatraman , Shehab Ahmed , Charalambos Konstantinou

Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…

最优化与控制 · 数学 2015-08-25 Nikolaos Theodorakatos , Nikolaos Manousakis , George Korres

The most commonly used weighted least square state estimator in power industry is nonlinear and formulated by using conventional measurements such as line flow and injection measurements. PMUs (Phasor Measurement Units) are gradually adding…

系统与控制 · 计算机科学 2017-03-22 Hossein A. Sangrody , Mohammad Taghi Ameli

The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is…

系统与控制 · 计算机科学 2015-05-19 K. G. Nagananda , Shalinee Kishore , Rick S. Blum

The lack of measurements in distribution grids poses a severe challenge for their monitoring: since there may not be enough sensors to achieve numerical observability, load forecasts (pseudo-measurements) are typically used, and thus an…

系统与控制 · 电气工程与系统科学 2019-08-09 Miguel Picallo , Adolfo Anta , Bart De Schutter

Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…

系统与控制 · 电气工程与系统科学 2020-09-08 Xiaozhou Yang , Nan Chen , Chao Zhai

The goal of this paper is to study the impact of the dynamic nature of bus voltage magnitudes and phase angles, which constitute the state of the power system, on the phasor measurement unit (PMU) placement problem. To facilitate this…

系统与控制 · 计算机科学 2013-11-18 K. G. Nagananda

This paper introduces an algorithm able to detect and localize the occurrance of a fault in an Active Distribution Network, using the measurements collected by Phasor Measurement Units (PMUs). First, a basic algorithm that works under the…

系统与控制 · 电气工程与系统科学 2022-04-13 Francesco Conte , Fabio D'Agostino , Bruno Gabriele , Giacomo-Piero Schiapparelli , Federico Silvestro

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the…

系统与控制 · 电气工程与系统科学 2020-04-16 Alexey Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer , M. Nicolai L. Lorenz-Meyer

In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…

最优化与控制 · 数学 2014-10-08 Junjian Qi , Kai Sun , Wei Kang

This paper presents an information-theoretic approach to address the phasor measurement unit (PMU) placement problem in electric power systems. Different from the conventional 'topological observability' based approaches, this paper…

最优化与控制 · 数学 2012-01-16 Qiao Li , Tao Cui , Yang Weng , Rohit Negi , Franz Franchetti , Marija D. Ilic

Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…

系统与控制 · 计算机科学 2016-07-12 Jian Du , Shaodan Ma , Yik-Chung Wu , H. Vincent Poor

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it…

系统与控制 · 电气工程与系统科学 2020-10-16 Hamed Haggi , Wei Sun , Junjian Qi

To provide real-time visibility of physics-based states, phasor measurement units (PMUs) are deployed throughout power networks. PMU data enable real-time grid monitoring and control -- and are essential in transitioning to smarter grids.…

系统与控制 · 电气工程与系统科学 2024-10-23 Mohamad H. Kazma , Ahmad F. Taha

A significant portion of the literature on fault localization assumes (more or less explicitly) that there are sufficient reliable measurements to guarantee that the system is observable. While several heuristics exist to break the…

系统与控制 · 计算机科学 2018-09-12 Mahdi Jamei , Anna Scaglione , Sean Peisert

Phasor Measurement Units (PMUs) are measurement devices long used in transmission systems and today even more essential for a proper monitoring of distribution grids. The expected massive penetration of distributed energy resources (DERs)…

系统与控制 · 电气工程与系统科学 2020-03-03 Carlo Guarnieri Calo\' Carducci , Gianluca Lipari , Nicola Giaquinto , Ferdinanda Ponci , Antonello Monti