Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype…

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…

仪器与探测器 · 物理学 2025-02-11 N. Li , X. Ren , H. Gao , Z. Zhang , Y. Zhang , C. Liu , H. Li , Z. Li

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama desert in Chile to observe the cosmic microwave background (CMB) radiation with unprecedented sensitivity. Simons Observatory…

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU…

Transition Edge Sensor (TES) bolometers are a well-established technology with a strong track record in experimental cosmology, making them ideal for current and future radio astronomy instruments. The Tomographic Ionized-carbon Mapping…

The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…

介观与纳米尺度物理 · 物理学 2011-02-01 D. J. Goldie , D. M. Glowacka , K. Rostem† , S. Withington

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability…

Superconducting Transition-Edge Sensor (TES) bolometers are used for cosmic microwave background (CMB) observations. We used a testbed to evaluate the thermal performance of TES bolometers in regard to the saturation power Psat and…

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is AC voltage biased at a well defined frequencies (between…

We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…

Transition Edge Sensors (TES) are superconducting microcalorimeters that can be used for single-photon detection with extremely low backgrounds. When they are within their superconducting transition region, small temperature fluctuations -…

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated…

We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a…

Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…

天体物理仪器与方法 · 物理学 2024-08-16 K. R. Ferguson , A. N. Bender , N. Whitehorn , T. W. Cecil

Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to gamma rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the…

天体物理仪器与方法 · 物理学 2024-04-03 N. Li , G. Liao , D. Yan , Y. Xu , Y. Zhang , Z. Liu , S. Yuan , Y. Zhang , H. Gao , Y. Li , Y. Gu , C. Liu , H. Li , Z. Li , X. Ren

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

天体物理仪器与方法 · 物理学 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

The next generation of Far-infrared and X-ray space observatories will require detector arrays with thousands of transition edge sensor (TES) pixel. It is extremely important to have a tool that is able to characterize all the pixels and…

仪器与探测器 · 物理学 2021-02-19 E. Taralli , P. Khosropanah , L. Gottardi , K. Nagayoshi , M. L. Ridder , M. P. Bruijn , J. R. Gao

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final…

We consider and compare candidate superconducting detector technologies that might be applied to the readout of cavity-axion haloscopes and similar fundamental physics experiments. We conclude that a transition edge sensor (TES) configured…

仪器与探测器 · 物理学 2024-03-21 David J. Goldie , Stafford Withington , Christopher N. Thomas