中文
相关论文

相关论文: Validation of the Quantum Physics Processes Underl…

200 篇论文

While spatial dose conformity delivered to a target volume has been pushed to its practical limits with advanced treatment planning and delivery, investigations in novel temporal dose delivery are unfolding new mechanisms. Recent advances…

Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it…

医学物理 · 物理学 2023-01-26 Serdar Charyyev , Chih-Wei Chang , Mingyao Zhu , Liyong Lin , Katja Langen , Anees Dhabaan

Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates. Methods: PSI Gantry 1 treated patients…

Laser-driven proton sources have long been developed with an eye on their potential for medical application to radiation therapy. These sources are compact, versatile, and show peculiar characteristics such as extreme instantaneous dose…

Purpose: Patient-specific ridge filters can modulate proton energy to obtain a conformal dose. We describe a new framework for optimization of filter design and spot maps to meet the unique demands of FLASH radiotherapy. We demonstrate an…

Background & Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials.…

Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material &…

FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate and online monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods…

Background: Ultra-high dose rate proton therapy shows promise in tissue sparing by enhancing therapeutic ratio through the FLASH effect. In radiotherapy, accurate in vivo dosimetry is crucial for quality assurance, but remains challenging…

Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain.…

Ultra-high dose rate radiation therapy (FLASH) based on proton irradiation is of major interest for cancer treatments but creates new challenges for dose monitoring. Amorphous hydrogenated silicon is known to be one of the most…

Ultra high dose rate electron beams also known as FLASH radiotherapy is becoming of importance in several preclinial cancer treatment studies. However, due to the dose rate used during the irradiation sessions, no real time dose monitoring…

医学物理 · 物理学 2022-08-19 Chloe Lahaye , Jean-Marc Fontbonne , Samuel Salvador

We investigated the effects of scanning speed, beam configuration, and dose-rate modeling on the FLASH effect in post-mastectomy proton transmission-beam (TB) planning and evaluated whether optimizing the spot-scanning path can enhance…

The FLASH effect, characterized by potential sparing of organs at risk (OAR) through ultra-high dose rate irradiation, has garnered significant attention for its capability to address indications previously untreatable at conventional dose…

医学物理 · 物理学 2024-10-16 S. Wuyckens , M. Chocan Vera , R. Nilsson , V. Wase , D. Di Perri , X. Geets , E. Sterpin , J. A. Lee

Proton therapy can achieve a highly targeted treatment by utilising the advantageous dosimetric characteristics of the Bragg Peak. Protons traversing through a material will deposit their maximum energy at the Bragg Peak through ionisation…

Purpose: The FLASH effect, which reduces the radiosensitivity of healthy tissue while maintaining tumor control at high dose rates, has shown potential for improving radiation therapy. Conformal FLASH proton therapy involves advanced…

医学物理 · 物理学 2023-04-13 Sylvain Deffet , Edmond Sterpin

FLASH-RT has proven beneficial in preclinical studies. However, the lack of accurate real time 2D dosimetry is a limiting factor. In this work, an innovative solution for 2D real time dosimetry in UHDR electron beams is presented. The…

We aim to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH radiotherapy using a pixelated semiconductor detector. Measurements of the time structure of FLASH irradiations were performed…

Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…

Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to…

‹ 上一页 1 2 3 10 下一页 ›