相关论文: First Results for the pLGAD Sensor for Low-Penetra…
The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event…
In this contribution, we present an innovative design of the Low-Gain Avalanche Diode (LGAD) gain layer, the p$^+$ implant responsible for the local and controlled signal multiplication. In the standard LGAD design, the gain layer is…
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy…
Low-Gain Avalanche Diode (LGAD) sensors, offering timing resolutions of the order of tens of picoseconds, are being widely adopted in particle physics experiments and related applications. As these applications scale to large numbers of…
Gain-layer degradation from exposure to radiation limits the use of Low-Gain Avalanche Diodes (LGADs) in high energy particle physics detector experiments. Proper understanding of how the gain-layer is destroyed is not available on a defect…
Low Gain Avalanche Detectors built on n-type substrate (nLGADs) have been developed by IMB-CNM to enhance the detection of low-penetrating particles, with a wide range of applications from medicine, industry to synergies with developments…
Two design innovations, low-gain avalanche (Low-Gain Avalance Diode, LGAD) and resistive read-out (Resistive Silicon Detector, RSD), have brought strong performance improvements to silicon sensors. Large signals, due to the added gain…
This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of…
The development of Low-Gain Avalanche Detectors has opened up the possibility of manufacturing silicon detectors with signal larger than that of traditional sensors. In this paper we explore the timing performance of Low-Gain Avalanche…
The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was…
The increasing concentration of greenhouse gases, notably CH4 and CO2, has fueled global temperature increases, intensifying concerns regarding the prevailing climate crisis. Effectively monitoring these gases demands a detector spanning…
This part of the conference proceeding provides a detailed overview of cutting-edge advancements in detector technologies, focusing on their optimization, characterization, and applications in particle physics experiments. Building on the…
Low Gain Avalanche Diode (LGAD) is applied for the High-Granularity Timing Detector (HGTD), and it will be used to upgrade the ATLAS experiment. The first batch IHEP-IME LGAD sensors were designed by the Institute of High Energy Physics…
We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of…
The detectors with $\mathcal{O}$(10) $\mu$m spatial resolution and $\mathcal{O}$(10) ps timing resolution construct powerful particle trackers for future hadron or lepton collider experiments. LGAD: Low-Gain-Avalanche-Diode is a…
AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP)…
High-energy physics detectors, like Low Gain Avalanche Detectors (LGADs) that will be used as fast timing detectors in the High Luminosity LHC experiments, have to exhibit a significant radiation tolerance. Thereby the impact of radiation…
This paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration…
The 4H-SiC material exhibits good detection performance, but there are still many problems like signal distortion and poor signal quality. The 4H-SiC low gain avalanche detector (LGAD) has been fabricated for the first time to solve these…
The performances of Low Gain Avalanche diode (LGAD) sensors from a neutron irradiation campaign with fluences of 0.8 x 10^15, 15 x 10^15 and 2.5 x 10^15 neq/cm2 are reported in this article. These LGAD sensors are developed by the Institute…