Background: Individual skull models of bone density and geometry are important when planning the expected transcranial ultrasound acoustic field and estimating mechanical and thermal safety in low-intensity transcranial ultrasound…

Transcranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under MRI guidance. CT imaging is used to estimate the acoustic properties that vary…

图像与视频处理 · 电气工程与系统科学 2022-10-27 Han Liu , Michelle K. Sigona , Thomas J. Manuel , Li Min Chen , Benoit M. Dawant , Charles F. Caskey

Transcranial MRI-guided focused ultrasound (TcMRgFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively under MRI guidance. It is clinically approved to thermally ablate regions of the…

计算机视觉与模式识别 · 计算机科学 2022-02-23 Han Liu , Michelle K. Sigona , Thomas J. Manuel , Li Min Chen , Charles F. Caskey , Benoit M. Dawant

Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull…

With the increasing popularity of PET-MR scanners in clinical applications, synthesis of CT images from MR has been an important research topic. Accurate PET image reconstruction requires attenuation correction, which is based on the…

计算机视觉与模式识别 · 计算机科学 2018-07-31 Snehashis Roy , John A. Butman , Dzung L. Pham

Transcranial ultrasound therapy uses focused acoustic energy to induce therapeutic bioeffects in the brain. Ultrasound must be transmitted through the skull, which is highly attenuating and heterogeneous, causing beam distortion, reducing…

Accurate targeting is critical for the effectiveness of transcranial focused ultrasound (tFUS) neuromodulation. While CT provides accurate skull acoustic properties, its ionizing radiation and poor soft tissue contrast limit clinical…

医学物理 · 物理学 2025-07-14 Hengyu Gao , Shaodong Ding , Ziyang Liu , Jiefu Zhang , Bolun Li , Zhiwu An , Li Wang , Jing Jing , Tao Liu , Yubo Fan , Zhongtao Hu

Ultrasound simulations used for treatment planning in transcranial ultrasound stimulation(TUS) currently depend on converting computed tomography(CT) images to acoustic properties. Aiming to reduce subject exposure to ionising radiation,…

The ability to synthesise Computed Tomography images - commonly known as pseudo CT, or pCT - from MRI input data is commonly assessed using an intensity-wise similarity, such as an L2-norm between the ground truth CT and the pCT. However,…

MRI-guided radiation treatment planning is widely applied because of its superior soft-tissue contrast and no ionization radiation compared to CT-based planning. In this regard, synthetic CT (sCT) images should be generated from the…

医学物理 · 物理学 2021-05-14 Abbas Bahrami , Alireza Karimian , Hossein Arabi

Synthetic CT image generation from MRI scan is necessary to create radiotherapy plans without the need of co-registered MRI and CT scans. The chosen baseline adversarial model with cycle consistency permits unpaired image-to-image…

图像与视频处理 · 电气工程与系统科学 2023-08-16 Denis Prokopenko , Joël Valentin Stadelmann , Heinrich Schulz , Steffen Renisch , Dmitry V. Dylov

Transcranial ultrasound is more and more used for therapy and imaging of the brain. However, the skull is a highly attenuating and aberrating medium, with different structures and acoustic properties between samples and even within a…

医学物理 · 物理学 2022-07-26 Celestine Angla , Benoit Larrat , Jean-Luc Gennisson , Sylvain Chatillon

Transcranial ultrasound simulations are increasingly used to predict in situ exposure parameters for ultrasound therapies in the brain. However, there can be considerable uncertainty in estimating the acoustic medium properties of the skull…

医学物理 · 物理学 2022-12-09 Antonio Stanziola , José A. Pineda-Pardo , Bradley Treeby

Computed tomography (CT) is a widely used imaging modality for medical diagnosis and treatment. In electroencephalography (EEG), CT imaging is necessary for co-registering with magnetic resonance imaging (MRI) and for creating more accurate…

医学物理 · 物理学 2019-06-12 Andreas D. Lauritzen , Xenophon Papademetris , Sergei Turovets , John A. Onofrey

Computed tomography (CT) is indispensable for clinical diagnosis and image-guided interventions but exposes patients to ionizing radiation, motivating the development of safer imaging alternatives. Ultrasound (US) is non-ionizing and widely…

计算机视觉与模式识别 · 计算机科学 2026-05-07 Sapna Sachan , Amulya Kumar Mahto

Providing more precise tissue attenuation information, synthetic computed tomography (sCT) generated from magnetic resonance imaging (MRI) contributes to improved radiation therapy treatment planning. In our study, we employ the advanced…

图像与视频处理 · 电气工程与系统科学 2024-09-11 Fuxin Fan , Jingna Qiu , Yixing Huang , Andreas Maier

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation…

图像与视频处理 · 电气工程与系统科学 2023-06-01 Shaoyan Pan , Elham Abouei , Jacob Wynne , Tonghe Wang , Richard L. J. Qiu , Yuheng Li , Chih-Wei Chang , Junbo Peng , Justin Roper , Pretesh Patel , David S. Yu , Hui Mao , Xiaofeng Yang

This paper strives to generate a synthetic computed tomography (CT) image from a magnetic resonance (MR) image. The synthetic CT image is valuable for radiotherapy planning when only an MR image is available. Recent approaches have made…

图像与视频处理 · 电气工程与系统科学 2021-07-20 Zenglin Shi , Pascal Mettes , Guoyan Zheng , Cees Snoek

Currently, MRI-only radiotherapy (RT) eliminates some of the concerns about using CT images in RT chains such as the registration of MR images to a separate CT, extra dose delivery, and the additional cost of repeated imaging. However, one…

医学物理 · 物理学 2021-03-03 Faeze Gholamiankhah , Samaneh Mostafapour , Hossein Arabi

Purpose: There is increasing interest in computed tomography (CT) image estimations from magnetic resonance (MR) images. The estimated CT images can be utilised for attenuation correction, patient positioning, and dose planning in…

统计方法学 · 统计学 2019-04-02 Fekadu L. Bayisa , Xijia Liu , Anders Garpebring , Jun Yu