相关论文: Low-rank flat-field correction for artifact reduct…

200 篇论文

Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…

医学物理 · 物理学 2023-02-03 Dennis Hein , Konstantinos Liappis , Fredrik Grönberg , Alma Eguizabal , Mats Persson

Classical methods for X-ray computed tomography are based on the assumption that the X-ray source intensity is known, but in practice, the intensity is measured and hence uncertain. Under normal operating conditions, when the exposure time…

数值分析 · 数学 2017-07-17 Hari Om Aggrawal , Martin Skovgaard Andersen , Sean Rose , Emil Y. Sidky

Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…

图像与视频处理 · 电气工程与系统科学 2024-02-12 Dhruvi Shah , Shruti Mehta , Ashish Agrawal , Shishir Purohit , Bhaskar Chaudhury

X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…

医学物理 · 物理学 2025-05-27 Yang Zou , Meili Qi , Jianhua Zhang , Difei Zhang , Shuwei Wang , Jiale Zhang , Shengkun Yao , Huaidong Jiang

Defective and inconsistent responses in CT detectors can cause ring and streak artifacts in the reconstructed images, making them unusable for clinical purposes. In recent years, several ring artifact reduction solutions have been proposed…

计算机视觉与模式识别 · 计算机科学 2026-02-13 Hongxu Yang , Levente Lippenszky , Edina Timko , Gopal Avinash

With the development of computed tomography (CT) imaging technology, it is possible to acquire multi-energy data by spectral CT. Being different from conventional CT, the X-ray energy spectrum of spectral CT is cutting into several narrow…

医学物理 · 物理学 2023-01-25 Yuanwei He , Li Zeng , Qiong Xu , Zhe Wang , Haijun Yu , Zhaoqiang Shen , Zhaojun Yang , Rifeng Zhou

We present a pixel-specific, measurement-driven correction that effectively minimizes errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to…

仪器与探测器 · 物理学 2019-06-25 Linda C. P. Croton , Gary Ruben , Kaye S. Morgan , David M. Paganin , Marcus J. Kitchen

Ring artifacts in computed tomography images, arising from the undesirable responses of detector units, significantly degrade image quality and diagnostic reliability. To address this challenge, we propose a dual-domain regularization model…

图像与视频处理 · 电气工程与系统科学 2024-03-18 Hongyang Zhu , Xin Lu , Yanwei Qin , Xinran Yu , Tianjiao Sun , Yunsong Zhao

Low performance pixels (LPP) in Computed Tomography (CT) detectors would lead to ring and streak artifacts in the reconstructed images, making them clinically unusable. In recent years, several solutions have been proposed to correct LPP…

计算机视觉与模式识别 · 计算机科学 2026-01-30 Hongxu Yang , Levente Lippenszky , Edina Timko , Lehel Ferenczi , Gopal Avinash

Inconsistent responses of X-ray detector elements lead to stripe artifacts in the sinogram data, which manifest as ring artifacts in the reconstructed CT images, severely degrading image quality. This paper proposes a method for correcting…

图像与视频处理 · 电气工程与系统科学 2025-07-01 Ligen Shi , Xu Jiang , YunZe Liu , Chang Liu , Ping Yang , Shifeng Guo , Xing Zhao

Limited angle problem is a challenging issue in x-ray computed tomography (CT) field. Iterative reconstruction methods that utilize the additional prior can suppress artifacts and improve image quality, but unfortunately require increased…

医学物理 · 物理学 2016-10-04 Hanming Zhang , Liang Li , Kai Qiao , Linyuan Wang , Bin Yan , Lei Li , Guoen Hu

Spectral computed tomography (CT) is an emerging technology, that generates a multienergy attenuation map for the interior of an object and extends the traditional image volume into a 4D form. Compared with traditional CT based on…

医学物理 · 物理学 2022-07-27 Xiang Chen , Wenjun Xia , Ziyuan Yang , Hu Chen , Yan Liu , Jiliu Zhou , Yi Zhang

Limited-angle computed tomography (CT) is often used in clinical applications such as C-arm CT for interventional imaging. However, CT images from limited angles suffers from heavy artifacts due to incomplete projection data. Existing…

计算机视觉与模式识别 · 计算机科学 2017-08-01 Jawook Gu , Jong Chul Ye

Low-rank decomposition (LRD) is a state-of-the-art method for visual data reconstruction and modelling. However, it is a very challenging problem when the image data contains significant occlusion, noise, illumination variation, and…

计算机视觉与模式识别 · 计算机科学 2017-08-08 Chen Chen , Baochang Zhang , Alessio Del Bue , Vittorio Murino

Computed Tomography (CT) using synchrotron radiation is a powerful technique that, compared to lab-CT techniques, boosts high spatial and temporal resolution while also providing access to a range of contrast-formation mechanisms. The…

图像与视频处理 · 电气工程与系统科学 2025-01-20 Jiayang Shi , Daniel M. Pelt , K. Joost Batenburg

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing…

图像与视频处理 · 电气工程与系统科学 2023-02-13 Abdulrahman M. Alanazi , Singanallur Venkatakrishnan , Gregery T. Buzzard , Charles A. Bouman

Deep neural network based methods have achieved promising results for CT metal artifact reduction (MAR), most of which use many synthesized paired images for training. As synthesized metal artifacts in CT images may not accurately reflect…

图像与视频处理 · 电气工程与系统科学 2020-07-09 Chuang Niu , Wenxiang Cong , Fenglei Fan , Hongming Shan , Mengzhou Li , Jimin Liang , Ge Wang

Ring artifacts are common artifacts in CT imaging, typically caused by inconsistent responses of detector units to X-rays, resulting in stripe artifacts in the projection data. Under circular scanning mode, such artifacts manifest as…

图像与视频处理 · 电气工程与系统科学 2025-04-16 Yunze Liu , Congyi Su , Xing Zhao

Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or…

计算机视觉与模式识别 · 计算机科学 2024-03-28 Mohammadreza Amirian , Daniel Barco , Ivo Herzig , Frank-Peter Schilling

Metal artifacts from high-attenuation implants severely degrade CT image quality, obscuring critical anatomical structures and posing a challenge for standard deep learning methods that require extensive paired training data. We propose a…

计算机视觉与模式识别 · 计算机科学 2026-04-08 Ahmet Rasim Emirdagi , Süleyman Aslan , Mısra Yavuz , Görkay Aydemir , Yunus Bilge Kurt , Nasrin Rahimi , Burak Can Biner , M. Akın Yılmaz