相关论文: Characteristics of a matrix proportional counter w…
A honeycomb detector consisting of a matrix of 96 closely packed hexagonal cells, each working as a proportional counter with a wire readout, was fabricated and tested at the CERN PS. The cell depth and the radial dimensions of the cell…
A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants…
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…
The Multi-Pixel Photon Counter (MPPC) or Silicon Photomultiplier (SiPM) can detect from a single photon to several thousand ones; it has high gain -$10^{5}$ to $10^{6}$-, low operation voltage -65 to 75 Vdc-, and small size -typically 3.85…
A new multiwire proportional chamber (MWPC) was designed and constructed for precision studies of neutron beta decay angular correlations. Its design has several novel features, including the use of low pressure neopentane as the MWPC gas…
In the T2K near neutrino detectors, about 60 000 Hamamatsu Multi-Pixel Photon Counters (MPPCs) will be used. The mass production of MPPC has started in February 2008.In order to perform quality assurance and to characterize each device, we…
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 10 eV. The method suggested in the assumption that hidden photons of the mass greater than…
Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…
We have developed a Multi-Pixel Photon Counter (MPPC) for the neutrino detectors of T2K experiment. About 64,000 MPPCs have been produced and tested in about a year. In order to characterize a large number of MPPCs, we have developed a…
Multi-Pixel Photon Counter (MPPC) has been recently emerged and realized as a great type of Silicon Photomultiplier to replace or compensate for the conventional vacuum-based Photomultiplier tubes. MPPC provides many striking features such…
New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a…
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…
We describe a work of a multi-cathode counter of the developed design in a single electron counting mode with a cathode made of aluminum alloy. The results of the calibration of the counter are presented. The coefficient of gas…
Combining high peak and high average power has long been a key challenge of ultrafast laser technology, crucial for applications such as laser-plasma acceleration and strong-field physics. A promising solution lies in post-compressed…
Multi-channel wire gas electron multipliers (MWGEM) with gaps between the electrodes of 1 and 3mm were investigated. The chamber of the MWGEM was filled with pure commercial neon gas at pressure of 0.4 or 1.0 bar and irradiated by…
A time projection chamber (TPC) based on a gaseous chamber with micro pixel electrodes (micro-PIC) has been developed for measuring three-dimensional tracks of charged particles. The micro-PIC with a detection area of 10 cm square consists…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method is suggested in the assumption that HP-photon mixing causes emission of…