中文
相关论文

相关论文: Sinogram upsampling using Primal-Dual UNet for und…

200 篇论文

The acquisition of Magnetic Resonance Imaging (MRI) is inherently slow. Inspired by recent advances in deep learning, we propose a framework for reconstructing MR images from undersampled data using a deep cascade of convolutional neural…

计算机视觉与模式识别 · 计算机科学 2017-03-03 Jo Schlemper , Jose Caballero , Joseph V. Hajnal , Anthony Price , Daniel Rueckert

Undersampling the k-space in MRI allows saving precious acquisition time, yet results in an ill-posed inversion problem. Recently, many deep learning techniques have been developed, addressing this issue of recovering the fully sampled MR…

图像与视频处理 · 电气工程与系统科学 2020-07-28 Mélanie Gaillochet , Kerem C. Tezcan , Ender Konukoglu

A major challenge in X-ray computed tomography (CT) is reducing radiation dose while maintaining high quality of reconstructed images. To reduce the radiation dose, one can reduce the number of projection views (sparse-view CT); however, it…

机器学习 · 统计学 2019-09-17 Xuehang Zheng , Il Yong Chun , Zhipeng Li , Yong Long , Jeffrey A. Fessler

During raw-data acquisition in CT imaging, diverse factors can degrade the collected sinograms, with undersampling and noise leading to severe artifacts and noise in reconstructed images and compromising diagnostic accuracy. Conventional…

计算机视觉与模式识别 · 计算机科学 2025-08-26 Xingyu Ai , Shaoyu Wang , Zhiyuan Jia , Ao Xu , Hongming Shan , Jianhua Ma , Qiegen Liu

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

计算机视觉与模式识别 · 计算机科学 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

In recent years, machine learning (ML) based reconstruction has been widely investigated and employed in cardiac magnetic resonance (CMR) imaging. ML-based reconstructions can deliver clinically acceptable image quality under substantially…

图像与视频处理 · 电气工程与系统科学 2024-11-18 Chi Zhang , Michael Loecher , Cagan Alkan , Mahmut Yurt , Shreyas S. Vasanawala , Daniel B. Ennis

Parallel magnetic resonance imaging has served as an effective and widely adopted technique for accelerating scans. The advent of sparse sampling offers aggressive acceleration, allowing flexible sampling and better reconstruction.…

医学物理 · 物理学 2019-09-09 Xinlin Zhang , Di Guo , Yiman Huang , Ying Chen , Liansheng Wang , Feng Huang , Xiaobo Qu

Recent studies on T1-assisted MRI reconstruction for under-sampled images of other modalities have demonstrated the potential of further accelerating MRI acquisition of other modalities. Most of the state-of-the-art approaches have achieved…

图像与视频处理 · 电气工程与系统科学 2021-11-15 Junwei Yang , Xiao-Xin Li , Feihong Liu , Dong Nie , Pietro Lio , Haikun Qi , Dinggang Shen

Computed Tomography (CT) is pivotal in industrial quality control and medical diagnostics. Sparse-view CT, offering reduced ionizing radiation, faces challenges due to its under-sampled nature, leading to ill-posed reconstruction problems.…

计算机视觉与模式识别 · 计算机科学 2024-11-06 Jiayang Shi , Junyi Zhu , Daniel M. Pelt , K. Joost Batenburg , Matthew B. Blaschko

Performing X-ray computed tomography (CT) examinations with less radiation has recently received increasing interest: in medical imaging this means less (potentially harmful) radiation for the patient; in non-destructive testing of…

医学物理 · 物理学 2018-09-25 Dragos Trinca , Eduard Libin

MRI with multiple protocols is commonly used for diagnosis, but it suffers from a long acquisition time, which yields the image quality vulnerable to say motion artifacts. To accelerate, various methods have been proposed to reconstruct…

图像与视频处理 · 电气工程与系统科学 2020-04-09 Bo Zhou , S. Kevin Zhou

Multi-contrast Magnetic Resonance Imaging (MRI) acquisitions from a single scan have tremendous potential to streamline exams and reduce imaging time. However, maintaining clinically feasible scan time necessitates significant…

图像与视频处理 · 电气工程与系统科学 2021-03-09 Ke Wang , Enhao Gong , Yuxin Zhang , Suchadrima Banerjee , Greg Zaharchuk , John Pauly

Magnetic resonance imaging (MRI) is increasingly utilized for image-guided radiotherapy due to its outstanding soft-tissue contrast and lack of ionizing radiation. However, geometric distortions caused by gradient nonlinearity (GNL) limit…

Ultra low radiation dose in X-ray Computed Tomography (CT) is an important clinical objective in order to minimize the risk of carcinogenesis. Compressed Sensing (CS) enables significant reductions in radiation dose to be achieved by…

The ability of deep image prior (DIP) to recover high-quality images from incomplete or corrupted measurements has made it popular in inverse problems in image restoration and medical imaging including magnetic resonance imaging (MRI).…

计算机视觉与模式识别 · 计算机科学 2024-02-09 Shijun Liang , Evan Bell , Qing Qu , Rongrong Wang , Saiprasad Ravishankar

Purpose: This study presents a variable resolution (VR) sampling and deep learning reconstruction approach for multi-spectral MRI near metal implants, aiming to reduce scan times while maintaining image quality. Background: The rising use…

图像与视频处理 · 电气工程与系统科学 2024-11-01 Azadeh Sharafi , Nikolai J. Mickevicius , Mehran Baboli , Andrew S. Nencka , Kevin M. Koch

Cone-beam computed tomography (CBCT) using only a few X-ray projection views enables faster scans with lower radiation dose, but the resulting severe under-sampling causes strong artifacts and poor spatial coverage. We address these…

图像与视频处理 · 电气工程与系统科学 2025-06-25 Minmin Yang , Huantao Ren , Senem Velipasalar

In this work, we investigate the application of deep learning methods for computed tomography in the context of having a low-data regime. As motivation, we review some of the existing approaches and obtain quantitative results after…

图像与视频处理 · 电气工程与系统科学 2021-04-20 Daniel Otero Baguer , Johannes Leuschner , Maximilian Schmidt

Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative…

图像与视频处理 · 电气工程与系统科学 2019-06-04 Shabab Bazrafkan , Vincent Van Nieuwenhove , Joris Soons , Jan De Beenhouwer , Jan Sijbers

X-ray computed tomography (CT) reconstructs cross-sectional images from projection data. However, ionizing X-ray radiation associated with CT scanning might induce cancer and genetic damage. Therefore, the reduction of radiation dose has…

图像与视频处理 · 电气工程与系统科学 2019-09-13 Huidong Xie , Hongming Shan , Wenxiang Cong , Xiaohua Zhang , Shaohua Liu , Ruola Ning , Ge Wang